MiniMed 700G Insulin Pump (MMT-1801, MMT-1805, MMT-1850, MMT-1851)
MiniMed 700G Insulin Pump (MMT-1801, MMT-1805, MMT-1850, MMT-1851)
All Medtronic MiniMed infusion pumps (Paradigm series, 600 series, and BLE 700 series) were found to be affected by unintended over- and under-delivery of insulin when the pump is elevated or lowered relative to the infusion site, respectively, because of changes in gravitational force impacting hydrostatic and hydrodynamic pressures. Insulin over-delivery, which can occur when the pump is elevated relative to the infusion site, can result in severe hypoglycemia, altered mental status, seizure, coma, or death. An under-delivery of insulin, which can occur at lowered pump height conditions relative to the infusion site, can result in severe hyperglycemia, dehydration, diabetic ketoacidosis, or death.
Allura Xper FD20/20; System Code: 722038;
Allura Xper FD20/20; System Code: 722038;
Philips has identified instances where X-ray imaging may not be initiated or may occur intermittently when using the wired foot switch.
Toyota Motor Engineering & Manufacturing - Fuel Pump May Fail
Toyota Motor Engineering & Manufacturing - Fuel Pump May Fail
Fuel pump failure can cause an engine stall, increasing the risk of a crash.
Forest River, Inc. - Incorrect Weight Listed on Label/FMVSS 110
Forest River, Inc. - Incorrect Weight Listed on Label/FMVSS 110
Incorrect weight information may lead to unintentionally overloading the vehicle, increasing the risk of a crash.
Brand Name: da Vinci S, Si Double Fenestrated Grasper Instrument Product Name: da Vinci S, Si Double Fenestrated Grasper Instrument Model/Catalog Number: 420189 Software Version: NA Product Description: EndoWrist Instruments or Da Vinci S/Si Reusable instruments, including blunt and sharp endoscopic dissectors, scissors, scalpels, forceps/pick-ups, needle holders, endoscopic retractors, electrocautery and accessories are intended for endoscopic manipulation of tissue, including grasping, cutting, blunt and sharp dissection, approximation, ligation, electrocautery, suturing, and delivery and placement of microwave and cryogenic ablation probes and accessories. Please refer to attached User Manual for additional details on intended use. All da Vinci S/Si reusable instruments with jaws use mechanical tungsten cables and pulleys to transmit motion from the input discs to the housing (on the proximal chassis), through the main shaft, and the distal instrument tip (inside the patient). Component: NA
Brand Name: da Vinci S, Si Double Fenestrated Grasper Instrument Product Name: da Vinci S, Si Double Fenestrated Grasper Instrument Model/Catalog Number: 420189 Software Version: NA Product Description: EndoWrist Instruments or Da Vinci S/Si Reusable instruments, including blunt and sharp endoscopic dissectors, scissors, scalpels, forceps/pick-ups, needle holders, endoscopic retractors, electrocautery and accessories are intended for endoscopic manipulation of tissue, including grasping, cutting, blunt and sharp dissection, approximation, ligation, electrocautery, suturing, and delivery and placement of microwave and cryogenic ablation probes and accessories. Please refer to attached User Manual for additional details on intended use. All da Vinci S/Si reusable instruments with jaws use mechanical tungsten cables and pulleys to transmit motion from the input discs to the housing (on the proximal chassis), through the main shaft, and the distal instrument tip (inside the patient). Component: NA
Due to increased complaints for broken/frayed grip cables for reusable instruments.
eTRAX Needle System Starter Kit 18G (for Aurora Trackers), Part Number 667-152
eTRAX Needle System Starter Kit 18G (for Aurora Trackers), Part Number 667-152
There was an error in inspection and programming of the eTRAX needle sensor for Aurora trackers. The result is a potential for the needle tip position to be incorrectly identified on the user interface.
Azurion 5 M12; System Code: (1)722227, (2)722231;
Azurion 5 M12; System Code: (1)722227, (2)722231;
Philips has identified instances where X-ray imaging may not be initiated or may occur intermittently when using the wired foot switch.
2.4 VOLT TAP LOCKING SCREW TAP TO 90MM. Part Number: 03.424.124-US.
2.4 VOLT TAP LOCKING SCREW TAP TO 90MM. Part Number: 03.424.124-US.
A full lot swap between VOLT Locking Screw Tap 03.424.124 lot 68900P9 and Cortical Screw Tap 03.424.126 lot 68982P8, resulting in the bones taps having an incorrect thread.
Philips Respironics Trilogy EV300, Software Version 1.05.15.00. Continuous home-use ventilator device.
Philips Respironics Trilogy EV300, Software Version 1.05.15.00. Continuous home-use ventilator device.
In some situations, the Obstruction Alarm does not trigger within the timeframe dictated by the relevant standards and may take up to four breaths.
Burlington Medical, Vest
Burlington Medical, Vest
Potential for attenuation degradation over time, decreasing the lifespan.
Prazosin Hydrochloride Capsules, USP, 1mg, 100-count bottle, Rx Only, Manufactured for: Biocon Pharma Inc., Iselin, NJ, Manufactured by: Appco Pharma LLC, Piscataway, NJ, NDC 70377-066-11.
Prazosin Hydrochloride Capsules, USP, 1mg, 100-count bottle, Rx Only, Manufactured for: Biocon Pharma Inc., Iselin, NJ, Manufactured by: Appco Pharma LLC, Piscataway, NJ, NDC 70377-066-11.
cGMP deviation: detection of Nitrosamine Drug Substance-Related Impurities, N-nitroso-prazosin impurity C (NNP) above acceptable limits.
Spray Dried Dairy Powder 25 kg bags or 1 metric ton totes
Spray Dried Dairy Powder 25 kg bags or 1 metric ton totes
Salmonella spp. identified in finished product testing
RefleXion X1 Radiotherapy System Model RXM1000, Part #800-00006-00
RefleXion X1 Radiotherapy System Model RXM1000, Part #800-00006-00
Due to a radiotherapy medical system software defect, when performing angular roll corrections followed by a repeat localization, the roll corrections applied in the initial localization scan are not carried through to treatment delivery leading to the treatment plan dose being delivered to the incorrect location, potentially a displacement of 5mm or higher, with a 10% to 20% underdose.
ALLURA Xper FD20 OR Table; System Code: (1) 722015, (2)722023, (3)722035;
ALLURA Xper FD20 OR Table; System Code: (1) 722015, (2)722023, (3)722035;
Philips has identified instances where X-ray imaging may not be initiated or may occur intermittently when using the wired foot switch.
Jiffy Original Composite Polisher Cups (Coarse) 12pk, REF 7011.
Jiffy Original Composite Polisher Cups (Coarse) 12pk, REF 7011.
Composite polisher cups may crumble and break apart easily, which could cause a delay in patient treatment.
Burlington Medical, Protective Sleeves.
Burlington Medical, Protective Sleeves.
Potential for attenuation degradation over time, decreasing the lifespan.
Allura Xper FD20/10; System Code: 722029;
Allura Xper FD20/10; System Code: 722029;
Philips has identified instances where X-ray imaging may not be initiated or may occur intermittently when using the wired foot switch.
MiniMed 740G Insulin Pump (MMT-1811, MMT-1812, MMT-1861, MMT-1862)
MiniMed 740G Insulin Pump (MMT-1811, MMT-1812, MMT-1861, MMT-1862)
All Medtronic MiniMed infusion pumps (Paradigm series, 600 series, and BLE 700 series) were found to be affected by unintended over- and under-delivery of insulin when the pump is elevated or lowered relative to the infusion site, respectively, because of changes in gravitational force impacting hydrostatic and hydrodynamic pressures. Insulin over-delivery, which can occur when the pump is elevated relative to the infusion site, can result in severe hypoglycemia, altered mental status, seizure, coma, or death. An under-delivery of insulin, which can occur at lowered pump height conditions relative to the infusion site, can result in severe hyperglycemia, dehydration, diabetic ketoacidosis, or death.
Magnesium Sulfate in Water for Injection, 4g/100 mL (40mg/mL) IV bag, further packaged in cartons of 12 x 100 mL IV bags, Rx only, Manufactured by: Amneal Pharmaceuticals Pvt. Ltd., Ahmedabad, 382110, India, Distributed by: Amneal Pharmaceuticals LLC, Bridgewater, NJ 08807, NDC 70121-1720-3.
Magnesium Sulfate in Water for Injection, 4g/100 mL (40mg/mL) IV bag, further packaged in cartons of 12 x 100 mL IV bags, Rx only, Manufactured by: Amneal Pharmaceuticals Pvt. Ltd., Ahmedabad, 382110, India, Distributed by: Amneal Pharmaceuticals LLC, Bridgewater, NJ 08807, NDC 70121-1720-3.
Product mix up: a foil pouch labeled "Magnesium Sulfate in Water for Injection, 4 g/100 mL" actually contained an IV bag of Tranexamic Acid instead.
Prickly Pear Jelly. 9 oz (268 g) glass bottle with gold cap.
Prickly Pear Jelly. 9 oz (268 g) glass bottle with gold cap.
Undeclared milk.
ALLURA Xper FD10F; System Code: 722002;
ALLURA Xper FD10F; System Code: 722002;
Philips has identified instances where X-ray imaging may not be initiated or may occur intermittently when using the wired foot switch.
Field Safety Notices: 30 March - 3 April 2026
Field Safety Notices: 30 March - 3 April 2026
List of Field Safety Notices for 30 March - 3 April 2026...
POPPING BOBA RTD STRAWBERRY DRAGON F/OOLONG TEA 12 X 13.8OZ
POPPING BOBA RTD STRAWBERRY DRAGON F/OOLONG TEA 12 X 13.8OZ
Packaging integrity issue that may compromise product quality .
Burlington Medical, Half Aprons.
Burlington Medical, Half Aprons.
Potential for attenuation degradation over time, decreasing the lifespan.