Reason for Recall / Hazard

The aluminum cast pivot joint that connects the base of the saw to the head assembly (which contains the saw blade) can crack under extreme pressure or force, causing the blade assembly to unexpectedly break free from the stationary base. This poses a laceration hazard to consumers.

Product Description & Identification

The recall involves all Wilton-brand, 10-inch Compound Mitre Saws, including models with the Laser Line feature with model numbers 99164 and 99192. The model number is written on a black label on the motor housing.

Affected Products

Wilton Mitre Saws

Additional Source Details

FieldValue
U R Lhttps://www.cpsc.gov/Recalls/2007/WMH-Tool-Group-Inc-Recalls-Wilton-Mitre-Saws-for-Laceration-Hazard
TitleWMH Tool Group Inc. Recalls Wilton Mitre Saws for Laceration Hazard
Images › 1 › U R Lhttps://www.cpsc.gov/~/link/8c53477d98484e378cf4f81b768a32ca.jpg
Images › 1 › CaptionRecalled Mitre Saw
Images › 2 › U R Lhttps://www.cpsc.gov/~/link/b30632d839cf4b13bb3d038cafeeadb6.jpg
Images › 2 › CaptionRecalled Mitre Saw
Hazards › NameThe aluminum cast pivot joint that connects the base of the saw to the head assembly (which contains the saw blade) can crack under extreme pressure or force, causing the blade assembly to unexpectedly break free from the stationary base. This poses a laceration hazard to consumers.
Injuries › NameWMH is aware of four reports of cracked pivot housings, one of which resulted in the separation of the saw blade from the base. No injuries have been reported relating to this hazard.
Products › NameWilton Mitre Saws
Products › TypeMiter Saws
Products › Category I D2047
Products › Number Of UnitsAbout 38,000
Recall I D3479
Remedies › NameConsumers should immediately stop using these saws, destroy and discard them. The firm is out of business. No remedy is available.
Retailers › NameHome and hardware stores nationwide from January 2002 through October 2006 for between $100 and $140.
Recall Date2006-11-08T00:00:00
DescriptionThe recall involves all Wilton-brand, 10-inch Compound Mitre Saws, including models with the Laser Line feature with model numbers 99164 and 99192. The model number is written on a black label on the motor housing.
Recall Number07025
Manufacturers › NameWMH Tool Group Inc., (WMH), of Elgin, Ill.
Consumer ContactThe firm is out of business. Call the CPSC hotline at 800-638-2772.