Home/Recalls/CPSC-07120
CPSCGeneral Alert

One World Technologies Recalls Throat Plates Sold with Ryobi Router Tables Due t...

Published: March 6, 2007Recall ID: 07120Category: generalCountry: US

Reason for Recall / Hazard

The throat plates do not securely snap into the router's table top bit opening. The throat plate can come loose during operation and be ejected from the table top, posing a laceration hazard to consumers.

Product Description & Identification

The recall involves Ryobi-brand router tables, with model number RT101, which is written on the table's data plate, located on its front leg. These tables were sold as part of the Ryobi combo kits with model numbers R161RTA and R162RTA. The combo kit model number is written on the packaging. A router table holds the router underneath the table. Instead of moving the router over the wood, the table allows the user to guide the wood for cutting. The throat plates are components of the table that consist of five yellow plastic rings. They serve as a guide for the router bit and provide a stable surface around the bit.

Affected Products

Ryobi Router Table Throat Plates

Additional Source Details

FieldValue
U R Lhttps://www.cpsc.gov/Recalls/2007/One-World-Technologies-Recalls-Throat-Plates-Sold-with-Ryobi-Router-Tables-Due-to-Laceration-Hazard
TitleOne World Technologies Recalls Throat Plates Sold with Ryobi Router Tables Due to Laceration Hazard
Images › 1 › U R Lhttps://www.cpsc.gov/~/link/a2992bed27c642c08e4c313774fa0ee0.jpg
Images › 1 › CaptionRyobi Router Bit Opening and Throat Plates
Images › 2 › U R Lhttps://www.cpsc.gov/~/link/7a0a8794ea71463085fd3feda95a2996.jpg
Images › 2 › CaptionRyobi Router Throat Plate (left) and new replacement (right)
Images › 3 › U R Lhttps://www.cpsc.gov/~/link/0719a2b093e441e4ab82b1fc83f82aaf.jpg
Images › 3 › CaptionRyobi Router Table
Hazards › NameThe throat plates do not securely snap into the router's table top bit opening. The throat plate can come loose during operation and be ejected from the table top, posing a laceration hazard to consumers.
Injuries › NameOne World Technologies has received three reports of throat plates coming loose during use. Two consumers were struck on the nose by the throat plate and received a minor cut and bruising.
Products › NameRyobi Router Table Throat Plates
Products › TypeRouters & Accessories
Products › Category I D2104
Products › Number Of UnitsAbout 100,000
Recall I D3560
Remedies › NameConsumers should immediately check their router tables to ensure that the throat plates securely snap into the router bit opening. If any throat plates do not securely snap into the table top, consumers should stop using the router table immediately and contact One Word Technologies for a free replacement set of throat plates.
Retailers › NameHome Depot stores nationwide between May 2004 and January 2007 for about $100 for the combo kits that include the router, router table and throat plates.
Recall Date2007-03-06T00:00:00
DescriptionThe recall involves Ryobi-brand router tables, with model number RT101, which is written on the table's data plate, located on its front leg. These tables were sold as part of the Ryobi combo kits with model numbers R161RTA and R162RTA. The combo kit model number is written on the packaging. A router table holds the router underneath the table. Instead of moving the router over the wood, the table allows the user to guide the wood for cutting. The throat plates are components of the table that consist of five yellow plastic rings. They serve as a guide for the router bit and provide a stable surface around the bit.
Recall Number07120
Manufacturers › NameOne World Technologies Inc., of Anderson, S.C.
Consumer ContactFor more information, consumers can call One World Technologies Inc. at (800) 525-2579 between 8 a.m. and 5 p.m. ET Monday through Friday, or go to the firm's Web site at www.ryobitools.com
Last Publish Date2014-05-23T00:00:00
Manufacturer Countries › CountryChina

Overview

  • Recalling FirmOne World Technologies Inc., of Anderson, S.C.
Official Agency Alert