Home/Recalls/CPSC-02524
CPSCGeneral Alert

CPSC, Viessmann Manufacturing Company (U.S.) Inc., Announce Recall of SR-RN-2 an...

Published: March 13, 2002Recall ID: 02524Category: generalCountry: US

Reason for Recall / Hazard

The controls have an electronic relay that may fail in a manner that will allow the burner to operate and by-pass the interlock with the flue damper. The interlock assures proper operation of the damper for removal of combustion gases. If the interlock fails, excess carbon monoxide emissions may occur.

Product Description & Identification

The recalled units, which are installed in Atola-RN Boilers, were manufactured between December 1998 and December 2001. This is the entire production of these controls. (The controls do not have a date code that can be seen by consumers.)

Affected Products

SR-RN-2 and SR-RN2R Boiler Control

Additional Source Details

FieldValue
U R Lhttps://www.cpsc.gov/Recalls/2002/CPSC-Viessmann-Manufacturing-Company-US-Inc-Announce-Recall-of-SR-RN-2-and-SR-RN2R-Boiler-Control-
TitleCPSC, Viessmann Manufacturing Company (U.S.) Inc., Announce Recall of SR-RN-2 and SR-RN2R Boiler Control
Images › U R Lhttps://www.cpsc.gov/s3fs-public/Picture_of_recalled_boiler_panel.jpg
Images › CaptionRecalled Boiler Panel
Hazards › NameThe controls have an electronic relay that may fail in a manner that will allow the burner to operate and by-pass the interlock with the flue damper. The interlock assures proper operation of the damper for removal of combustion gases. If the interlock fails, excess carbon monoxide emissions may occur.
Injuries › NameNo injuries have been reported.
Products › NameSR-RN-2 and SR-RN2R Boiler Control
Products › TypeBoilers & Accessories
Products › Category I D1856
Products › Number Of Units190
Recall I D2247
Remedies › NameConsumers who have one of these boilers should contact their local distributor or Ms. Ulli Hiltz, the Viessmann Manufacturing Company contact. Viessmann Manufacturing Company will install a wiring module in suspect boilers which will put a redundant switch in series with the switch that may erroneously close and by-pass the safety interlock with flue damper. Viessmann Manufacturing Company has contacted distributors and wholesalers and made arrangements for them to contact customers and make arrangements to retrofit the Atola-RN Boilers with SR-RN2 or SR-RN2R Controls.
Retailers › NameThe boilers were sold nationwide by wholesalers and distributors.
Recall Date2002-03-13T00:00:00
DescriptionThe recalled units, which are installed in Atola-RN Boilers, were manufactured between December 1998 and December 2001. This is the entire production of these controls. (The controls do not have a date code that can be seen by consumers.)
Recall Number02524
Manufacturers › NameViessmann Manufacturing Company (U.S.), of Warwick, R.I.
Consumer ContactMs. Ulli Hiltz, the Viessmann Manufacturing Company contact, can be reached at 888-843-2772 between 8:30am and 5:00 pm ET Monday through Friday.
Last Publish Date2025-10-31T00:00:00

Overview

  • Recalling FirmViessmann Manufacturing Company (U.S.), of Warwick, R.I.
Official Agency Alert