eTRAX Needle System Starter Kit 16G(for Aurora Trackers), Part Number 667-151
eTRAX Needle System Starter Kit 16G(for Aurora Trackers), Part Number 667-151
There was an error in inspection and programming of the eTRAX needle sensor for Aurora trackers. The result is a potential for the needle tip position to be incorrectly identified on the user interface.
POPPING BOBA RTD PEACH OOLONG TEA 12 X 13.8OZ
POPPING BOBA RTD PEACH OOLONG TEA 12 X 13.8OZ
Packaging integrity issue that may compromise product quality .
ALLURA Xper FD10F; System Code: 722002;
ALLURA Xper FD10F; System Code: 722002;
Philips has identified instances where X-ray imaging may not be initiated or may occur intermittently when using the wired foot switch.
Prazosin Hydrochloride Capsules, USP, 2mg, 100-count bottle, Rx Only, Manufactured for: Biocon Pharma Inc., Iselin, NJ, Manufactured by: Appco Pharma LLC, Piscataway, NJ, NDC 70377-067-11.
Prazosin Hydrochloride Capsules, USP, 2mg, 100-count bottle, Rx Only, Manufactured for: Biocon Pharma Inc., Iselin, NJ, Manufactured by: Appco Pharma LLC, Piscataway, NJ, NDC 70377-067-11.
cGMP deviation: detection of Nitrosamine Drug Substance-Related Impurities, N-nitroso-prazosin impurity C (NNP) above acceptable limits.
ALLURA Xper FD20 OR Table; System Code: (1) 722015, (2)722023, (3)722035;
ALLURA Xper FD20 OR Table; System Code: (1) 722015, (2)722023, (3)722035;
Philips has identified instances where X-ray imaging may not be initiated or may occur intermittently when using the wired foot switch.
Burlington Medical, Vest
Burlington Medical, Vest
Potential for attenuation degradation over time, decreasing the lifespan.
Burlington Medical, Wrap Aprons.
Burlington Medical, Wrap Aprons.
Potential for attenuation degradation over time, decreasing the lifespan.
Spray Dried Dairy Powder 25 kg bags or 1 metric ton totes
Spray Dried Dairy Powder 25 kg bags or 1 metric ton totes
Salmonella spp. identified in finished product testing
Prazosin Hydrochloride Capsules, USP, 1mg, 100-count bottle, Rx Only, Manufactured for: Biocon Pharma Inc., Iselin, NJ, Manufactured by: Appco Pharma LLC, Piscataway, NJ, NDC 70377-066-11.
Prazosin Hydrochloride Capsules, USP, 1mg, 100-count bottle, Rx Only, Manufactured for: Biocon Pharma Inc., Iselin, NJ, Manufactured by: Appco Pharma LLC, Piscataway, NJ, NDC 70377-066-11.
cGMP deviation: detection of Nitrosamine Drug Substance-Related Impurities, N-nitroso-prazosin impurity C (NNP) above acceptable limits.
BD Kiestra" ReadA; Catalog No.: 446948.
BD Kiestra" ReadA; Catalog No.: 446948.
In certain situations, following a system reboot, one or more modules may have become unreachable via the remote connectivity interface. When this occurred, there was potential for delays in plate retrieval from the incubator while connectivity was restored. This issue was intermittent and did not affect test results, performance of the assay, or sample integrity.
Paradigm REAL-Time Veo Insulin Pump (MMT-554, MMT-754)
Paradigm REAL-Time Veo Insulin Pump (MMT-554, MMT-754)
All Medtronic MiniMed infusion pumps (Paradigm series, 600 series, and BLE 700 series) were found to be affected by unintended over- and under-delivery of insulin when the pump is elevated or lowered relative to the infusion site, respectively, because of changes in gravitational force impacting hydrostatic and hydrodynamic pressures. Insulin over-delivery, which can occur when the pump is elevated relative to the infusion site, can result in severe hypoglycemia, altered mental status, seizure, coma, or death. An under-delivery of insulin, which can occur at lowered pump height conditions relative to the infusion site, can result in severe hyperglycemia, dehydration, diabetic ketoacidosis, or death.
MiniMed 740G Insulin Pump (MMT-1811, MMT-1812, MMT-1861, MMT-1862)
MiniMed 740G Insulin Pump (MMT-1811, MMT-1812, MMT-1861, MMT-1862)
All Medtronic MiniMed infusion pumps (Paradigm series, 600 series, and BLE 700 series) were found to be affected by unintended over- and under-delivery of insulin when the pump is elevated or lowered relative to the infusion site, respectively, because of changes in gravitational force impacting hydrostatic and hydrodynamic pressures. Insulin over-delivery, which can occur when the pump is elevated relative to the infusion site, can result in severe hypoglycemia, altered mental status, seizure, coma, or death. An under-delivery of insulin, which can occur at lowered pump height conditions relative to the infusion site, can result in severe hyperglycemia, dehydration, diabetic ketoacidosis, or death.
Burlington Medical, Frontal Aprons
Burlington Medical, Frontal Aprons
Potential for attenuation degradation over time, decreasing the lifespan.
MiniMed 640G Insulin Pump (MMT-1711, MMT-1712, MMT-1751, MMT-1752)
MiniMed 640G Insulin Pump (MMT-1711, MMT-1712, MMT-1751, MMT-1752)
All Medtronic MiniMed infusion pumps (Paradigm series, 600 series, and BLE 700 series) were found to be affected by unintended over- and under-delivery of insulin when the pump is elevated or lowered relative to the infusion site, respectively, because of changes in gravitational force impacting hydrostatic and hydrodynamic pressures. Insulin over-delivery, which can occur when the pump is elevated relative to the infusion site, can result in severe hypoglycemia, altered mental status, seizure, coma, or death. An under-delivery of insulin, which can occur at lowered pump height conditions relative to the infusion site, can result in severe hyperglycemia, dehydration, diabetic ketoacidosis, or death.
Burlington Medical, Blockers.
Burlington Medical, Blockers.
Potential for attenuation degradation over time, decreasing the lifespan.
RefleXion X1 Radiotherapy System Model RXM1000, Part #800-00006-00
RefleXion X1 Radiotherapy System Model RXM1000, Part #800-00006-00
Due to a radiotherapy medical system software defect, when performing angular roll corrections followed by a repeat localization, the roll corrections applied in the initial localization scan are not carried through to treatment delivery leading to the treatment plan dose being delivered to the incorrect location, potentially a displacement of 5mm or higher, with a 10% to 20% underdose.
Jiffy Original Composite Polisher Cups (Coarse) 12pk, REF 7011.
Jiffy Original Composite Polisher Cups (Coarse) 12pk, REF 7011.
Composite polisher cups may crumble and break apart easily, which could cause a delay in patient treatment.
eTRAX Needle Sensor - 12G (for Aurora Trackers), Part Number 667-156
eTRAX Needle Sensor - 12G (for Aurora Trackers), Part Number 667-156
There was an error in inspection and programming of the eTRAX needle sensor for Aurora trackers. The result is a potential for the needle tip position to be incorrectly identified on the user interface.
Prickly Pear Jelly. 9 oz (268 g) glass bottle with gold cap.
Prickly Pear Jelly. 9 oz (268 g) glass bottle with gold cap.
Undeclared milk.
MiniMed 630G Insulin Pump (MMT-1714, MMT-1715, MMT-1754, MMT-1755)
MiniMed 630G Insulin Pump (MMT-1714, MMT-1715, MMT-1754, MMT-1755)
All Medtronic MiniMed infusion pumps (Paradigm series, 600 series, and BLE 700 series) were found to be affected by unintended over- and under-delivery of insulin when the pump is elevated or lowered relative to the infusion site, respectively, because of changes in gravitational force impacting hydrostatic and hydrodynamic pressures. Insulin over-delivery, which can occur when the pump is elevated relative to the infusion site, can result in severe hypoglycemia, altered mental status, seizure, coma, or death. An under-delivery of insulin, which can occur at lowered pump height conditions relative to the infusion site, can result in severe hyperglycemia, dehydration, diabetic ketoacidosis, or death.
Toyota Motor Engineering & Manufacturing - Fuel Pump May Fail
Toyota Motor Engineering & Manufacturing - Fuel Pump May Fail
Fuel pump failure can cause an engine stall, increasing the risk of a crash.
Forest River, Inc. - Incorrect Weight Listed on Label/FMVSS 110
Forest River, Inc. - Incorrect Weight Listed on Label/FMVSS 110
Incorrect weight information may lead to unintentionally overloading the vehicle, increasing the risk of a crash.
Vue Motion V12. Product Number: 1017979.
Vue Motion V12. Product Number: 1017979.
Potential that mis-ordered frames in Vue Motion during dynamic cine runs may cause images frames to display out of sequence.
eTRAX Needle System Starter Kit 12G (for Aurora Trackers), Part Number 667-149
eTRAX Needle System Starter Kit 12G (for Aurora Trackers), Part Number 667-149
There was an error in inspection and programming of the eTRAX needle sensor for Aurora trackers. The result is a potential for the needle tip position to be incorrectly identified on the user interface.