Dispositivos Médicos Recalls

Defective surgical instruments, diagnostic equipment, and health device recalls.

Showing 24 of 2,119 results
Medical DeviceUSFDA Devices

INFINION CX LEAD KIT, 50CM, Model: SC-2317-50, Material: M365SC2317500; INFINION CX LEAD KIT, 70CM, Model: SC-2317-70, Material: M365SC2317700. part of the Boston Scientific Spinal Cord Stimulator (SCS) Systems.

Boston Scientific Neuromodulation Corporation
FDA DevicesClass I

INFINION CX LEAD KIT, 50CM, Model: SC-2317-50, Material: M365SC2317500; INFINION CX LEAD KIT, 70CM, Model: SC-2317-70, Material: M365SC2317700. part of the Boston Scientific Spinal Cord Stimulator (SCS) Systems.

Spinal cord stimulation system lead body may be exposed to stress at the anchor site. This may result in high impedance measurements or lead fractures, which may lead to inadequate stimulation, additional intervention, including lead explant and replacement.

Aug 12, 2026Boston Scientific Neuromodulation Corporation
Medical DeviceUSFDA Devices

Merge PACS, medical imaging diagnostic workstation

Merge Healthcare, Inc.
FDA DevicesClass II

Merge PACS, medical imaging diagnostic workstation

Thumbnails from a previously opened patient study may be displayed in the Thumbnail Bar while a different patient study is currently open.

Aug 12, 2026Merge Healthcare, Inc.
Medical DeviceUSFDA Devices

FilmArray NGDS Warrior Panel REF NGDS-ASY-0007 UDI-DI code: (01)00851458005136 The FilmArray NGDS Warrior Panel is a qualitative, multiplexed, nucleic acid-based in vitro diagnostic test intended for use with the FilmArray 2.0 system. The FilmArray NGDS Warrior Panel detects and identifies Bacillus anthracis, Yersinia pestis, Francisella tularensis, Coxiella burnetii, Ebola virus, and Marburg virus nucleic acids directly from human whole blood (EDTA).

Biofire Defense
FDA DevicesClass II

FilmArray NGDS Warrior Panel REF NGDS-ASY-0007 UDI-DI code: (01)00851458005136 The FilmArray NGDS Warrior Panel is a qualitative, multiplexed, nucleic acid-based in vitro diagnostic test intended for use with the FilmArray 2.0 system. The FilmArray NGDS Warrior Panel detects and identifies Bacillus anthracis, Yersinia pestis, Francisella tularensis, Coxiella burnetii, Ebola virus, and Marburg virus nucleic acids directly from human whole blood (EDTA).

Firm has identified mismatches between the outbreak strain and the reference strain used in the development of its qualitative, multiplexed, nucleic acid-based in vitro diagnostic panel test.

Aug 12, 2026Biofire Defense
Medical DeviceUSFDA Devices

Brand Name: COAPTIUM CONNECT Product Name: COAPTIUM CONNECT Model/Catalog Number: NCOCO2075 Software Version: N/A Product Description: In situ polymerizing peripheral nerve repair device Component: No

TISSIUM SA
FDA DevicesClass II

Brand Name: COAPTIUM CONNECT Product Name: COAPTIUM CONNECT Model/Catalog Number: NCOCO2075 Software Version: N/A Product Description: In situ polymerizing peripheral nerve repair device Component: No

Currently labeled shelf life of 36 months is not substantiated by real-time data. Devices will be relabeled to reflect revised shelf life of 26 months. The use of a medical device beyond its validated shelf life may result in perioperative breakage of the device rendering device unusable; worst-case outcome would be revision surgery.

Aug 12, 2026TISSIUM SA
Medical DeviceUSFDA Devices

Intramedullary Bone Saw Blade Assembly Model/Catalog Number: 475620 Product Description: Intramedullary Bone Saw Blade Assembly 12mm

Biomet, Inc.
FDA DevicesClass II

Intramedullary Bone Saw Blade Assembly Model/Catalog Number: 475620 Product Description: Intramedullary Bone Saw Blade Assembly 12mm

Zimmer Biomet is conducting a medical device recall removal for various sizes of the Intramedullary Bone Saw Blade Assembly due to potential sterile barrier packaging damage caused by an exposed saw blade.

Aug 12, 2026Biomet, Inc.
Medical DeviceUSFDA Devices

Radial Jaw 4 Large Capacity Biopsy Forceps with the following descriptions and UPN: 1. Radial Jaw 4 LC 240cm Box 20; Outer Box UPN: M00513321; Inner Box UPN: M00513320. 2. Radial Jaw 4 LC 240cm Box 40; Outer Box UPN: M00513322; Inner Box UPN: M00513320. 3. Radial Jaw 4 LC w/Needle 240cm Box 20; Outer Box UPN: M00513331; Inner Box UPN: M00513330. 4. Radial Jaw 4 LC w/Needle 240cm Box 40; Outer Box UPN: M00513332; Inner Box UPN: M00513330. 5. Radial Jaw 4 LC w/Needle 240cm Box 5; Outer Box UPN: M00513333; Inner Box UPN: M00513330.

Boston Scientific Corporation
FDA DevicesClass II

Radial Jaw 4 Large Capacity Biopsy Forceps with the following descriptions and UPN: 1. Radial Jaw 4 LC 240cm Box 20; Outer Box UPN: M00513321; Inner Box UPN: M00513320. 2. Radial Jaw 4 LC 240cm Box 40; Outer Box UPN: M00513322; Inner Box UPN: M00513320. 3. Radial Jaw 4 LC w/Needle 240cm Box 20; Outer Box UPN: M00513331; Inner Box UPN: M00513330. 4. Radial Jaw 4 LC w/Needle 240cm Box 40; Outer Box UPN: M00513332; Inner Box UPN: M00513330. 5. Radial Jaw 4 LC w/Needle 240cm Box 5; Outer Box UPN: M00513333; Inner Box UPN: M00513330.

Potential for breach in sterile barrier of device packaging.

Aug 12, 2026Boston Scientific Corporation
Medical DeviceUSFDA Devices

munevo DRIVE and munevo DRIVE r-net Powered Wheelchair Hands-Free Control Application/Smart Glasses Interface/Wheelchair Head Control System

MUNEVO GMBH
FDA DevicesClass II

munevo DRIVE and munevo DRIVE r-net Powered Wheelchair Hands-Free Control Application/Smart Glasses Interface/Wheelchair Head Control System

A software issue may cause the wheelchair's driving mechanism to fall out of calibration. When this occurs, the device may experience unexpected steering drift or imprecise control while driving the wheelchair. The wheelchair may veer from its intended path, which may cause in low-speed collision, tipping, or injuries to user or bystanders.

Aug 12, 2026MUNEVO GMBH
Medical DeviceUSFDA Devices

Brand Name: COAPTIUM CONNECT Product Name: COAPTIUM CONNECT Model/Catalog Number: NCOCO5010 Software Version: N/A Product Description: In situ polymerizing peripheral nerve repair device Component: No

TISSIUM SA
FDA DevicesClass II

Brand Name: COAPTIUM CONNECT Product Name: COAPTIUM CONNECT Model/Catalog Number: NCOCO5010 Software Version: N/A Product Description: In situ polymerizing peripheral nerve repair device Component: No

Currently labeled shelf life of 36 months is not substantiated by real-time data. Devices will be relabeled to reflect revised shelf life of 26 months. The use of a medical device beyond its validated shelf life may result in perioperative breakage of the device rendering device unusable; worst-case outcome would be revision surgery.

Aug 12, 2026TISSIUM SA
Medical DeviceUSFDA Devices

Brand Name: U2 Total Knee System Product Name: Femoral valgus offset adaptor, 2mm, 4mm, 6mm, left and Femoral valgus offset adaptor, 2mm, 4mm, 6mm, right Model/Catalog Number: 9323-5335, 9323-5337, 9323-5339 and 9323-5336, 9323-5338, 9323-5340 Software Version: N/A Product Description: Manual Orthopedic Surgical Instrument Component: No

United Orthopedic Corp.
FDA DevicesClass II

Brand Name: U2 Total Knee System Product Name: Femoral valgus offset adaptor, 2mm, 4mm, 6mm, left and Femoral valgus offset adaptor, 2mm, 4mm, 6mm, right Model/Catalog Number: 9323-5335, 9323-5337, 9323-5339 and 9323-5336, 9323-5338, 9323-5340 Software Version: N/A Product Description: Manual Orthopedic Surgical Instrument Component: No

Due to an incomplete process of the component screw by a subcontractor which prevents the properly assembling of stem trail.

Aug 12, 2026United Orthopedic Corp.
Medical DeviceUSFDA Devices

Brand Name: COAPTIUM CONNECT Product Name: COAPTIUM CONNECT Model/Catalog Number: NCOCO6010 Software Version: N/A Product Description: In situ polymerizing peripheral nerve repair device Component: No

TISSIUM SA
FDA DevicesClass II

Brand Name: COAPTIUM CONNECT Product Name: COAPTIUM CONNECT Model/Catalog Number: NCOCO6010 Software Version: N/A Product Description: In situ polymerizing peripheral nerve repair device Component: No

Currently labeled shelf life of 36 months is not substantiated by real-time data. Devices will be relabeled to reflect revised shelf life of 26 months. The use of a medical device beyond its validated shelf life may result in perioperative breakage of the device rendering device unusable; worst-case outcome would be revision surgery.

Aug 12, 2026TISSIUM SA
Medical DeviceUSFDA Devices

Merge OrthoPACS, medical imaging diagnostic workstation

Merge Healthcare, Inc.
FDA DevicesClass II

Merge OrthoPACS, medical imaging diagnostic workstation

Thumbnails from a previously opened patient study may be displayed in the Thumbnail Bar while a different patient study is currently open.

Aug 12, 2026Merge Healthcare, Inc.
Medical DeviceUSFDA Devices

Brand Name: Quantum Rehab Product Name: Q6 Edge HD Model/Catalog Number: Q6 Edge HD Software Version: 2.0.11, new version: 2.0.13 Product Description: Wheelchair, Powered (ITI), 890.3860 Component: Controller

Pride Mobility Products Corp.
FDA DevicesClass II

Brand Name: Quantum Rehab Product Name: Q6 Edge HD Model/Catalog Number: Q6 Edge HD Software Version: 2.0.11, new version: 2.0.13 Product Description: Wheelchair, Powered (ITI), 890.3860 Component: Controller

If the "Remind Me Later" option is selected for user reminders, reminder pop-up messages may appear while the wheelchair is in use. If this occurs while driving the wheelchair, the wheelchair may perform an unexpected park brake stop, which may result in fall or injury. If this occurs while not driving the wheelchair, the control system may crash and remain in pre-operational mode.

Aug 12, 2026Pride Mobility Products Corp.
Medical DeviceUSFDA Devices

Intramedullary Bone Saw Blade Assembly Model/Catalog Number: 475630 Product Description: Intramedullary Bone Saw Blade Assembly 14mm

Biomet, Inc.
FDA DevicesClass II

Intramedullary Bone Saw Blade Assembly Model/Catalog Number: 475630 Product Description: Intramedullary Bone Saw Blade Assembly 14mm

Zimmer Biomet is conducting a medical device recall removal for various sizes of the Intramedullary Bone Saw Blade Assembly due to potential sterile barrier packaging damage caused by an exposed saw blade.

Aug 12, 2026Biomet, Inc.
Medical DeviceUSFDA Devices

5-PLASMA Bivalirudin Calibrator, Model Number 5D-46905

Aniara Diagnostica LLC
FDA DevicesClass II

5-PLASMA Bivalirudin Calibrator, Model Number 5D-46905

Stability issues with the reconstituted lyophilized human plasma and bivalirudin matrix have been identified. These stability issues lead to a degradation of measurable bivalirudin in the controls, calibrators, and linearity values.

Aug 12, 2026Aniara Diagnostica LLC
Medical DeviceUSFDA Devices

Brand Name: COAPTIUM CONNECT Product Name: COAPTIUM CONNECT Model/Catalog Number: NCOCO1575 Software Version: N/A Product Description: In situ polymerizing peripheral nerve repair device Component: No

TISSIUM SA
FDA DevicesClass II

Brand Name: COAPTIUM CONNECT Product Name: COAPTIUM CONNECT Model/Catalog Number: NCOCO1575 Software Version: N/A Product Description: In situ polymerizing peripheral nerve repair device Component: No

Currently labeled shelf life of 36 months is not substantiated by real-time data. Devices will be relabeled to reflect revised shelf life of 26 months. The use of a medical device beyond its validated shelf life may result in perioperative breakage of the device rendering device unusable; worst-case outcome would be revision surgery.

Aug 12, 2026TISSIUM SA
Medical DeviceUSFDA Devices

Brand Name: Quantum rehab Product Name: Q6 Edge 2.0 Model/Catalog Number: Q6 Edge 2.0 Software Version: 2.0.11, new version: 2.0.13 Product Description: Wheelchair, Powered (ITI), 890.3860 Component: Controller

Pride Mobility Products Corp.
FDA DevicesClass II

Brand Name: Quantum rehab Product Name: Q6 Edge 2.0 Model/Catalog Number: Q6 Edge 2.0 Software Version: 2.0.11, new version: 2.0.13 Product Description: Wheelchair, Powered (ITI), 890.3860 Component: Controller

If the "Remind Me Later" option is selected for user reminders, reminder pop-up messages may appear while the wheelchair is in use. If this occurs while driving the wheelchair, the wheelchair may perform an unexpected park brake stop, which may result in fall or injury. If this occurs while not driving the wheelchair, the control system may crash and remain in pre-operational mode.

Aug 12, 2026Pride Mobility Products Corp.
Medical DeviceUSFDA Devices

STRYKER PKG., SINGLE SPIKE TUBE SET, Catalog Number 0250070530

Stryker Corporation
FDA DevicesClass II

STRYKER PKG., SINGLE SPIKE TUBE SET, Catalog Number 0250070530

There has been an increased amount in reported complaints consistently describing leaking from the handpiece during use.

Aug 12, 2026Stryker Corporation
Medical DeviceUSFDA Devices

Neuroguard IEP 3 in 1 Carotid Stent and Post-Dilation Balloon System with Integrated Embolic Protection (Neuroguard IEP System), REF: NG-0630-140-2, NG-0640-140-2, NG-0730-140-2, NG-0740-140-2, NG-NV-6-30, NG-NV-6-40, NG-NV-7-30, NG-NV-7-40

Contego Medical, Inc
FDA DevicesClass II

Neuroguard IEP 3 in 1 Carotid Stent and Post-Dilation Balloon System with Integrated Embolic Protection (Neuroguard IEP System), REF: NG-0630-140-2, NG-0640-140-2, NG-0730-140-2, NG-0740-140-2, NG-NV-6-30, NG-NV-6-40, NG-NV-7-30, NG-NV-7-40

Carotid stent and post-dilation balloon system with integrated embolic protection system has an integrated filter, that due to a wire-to-filter-bond issue, may fail to open following sheath retraction; and if this condition were to occur during a procedure, the result may be loss of intended integrated embolic protection.

Aug 12, 2026Contego Medical, Inc
Medical DeviceUSFDA Devices

Philips Azurion under the following System Descriptions and corresponding model numbers: 1. Azurion 3 M12; Model Numbers: 722063, 722221. 2. Azurion 3 M15; Model Numbers: 722064, 722222, 722280. 3. Azurion 5 M12; Model Number: 722227. 4. Azurion 5 M20; Model Numbers: 722228, 722281. 5. Azurion 7 B12; Model Numbers: 722067, 722225. 6. Azurion 7 B20; Model Numbers: 722068, 722226. 7. Azurion 7 M12; Model Numbers: 722078, 722223. 8. Azurion 7 M20; Model Numbers: 722079, 722224, 722282. Interventional Fluoroscopic X-Ray System.

PHILIPS MEDICAL SYSTEMS NEDERLAND B.V.
FDA DevicesClass II

Philips Azurion under the following System Descriptions and corresponding model numbers: 1. Azurion 3 M12; Model Numbers: 722063, 722221. 2. Azurion 3 M15; Model Numbers: 722064, 722222, 722280. 3. Azurion 5 M12; Model Number: 722227. 4. Azurion 5 M20; Model Numbers: 722228, 722281. 5. Azurion 7 B12; Model Numbers: 722067, 722225. 6. Azurion 7 B20; Model Numbers: 722068, 722226. 7. Azurion 7 M12; Model Numbers: 722078, 722223. 8. Azurion 7 M20; Model Numbers: 722079, 722224, 722282. Interventional Fluoroscopic X-Ray System.

Potential Loss of imaging functionality, loss of motorized movement, or loss of data due to unauthorized Hard Disk Drives.

Aug 12, 2026PHILIPS MEDICAL SYSTEMS NEDERLAND B.V.
Medical DeviceUSFDA Devices

Syva Emit Disopyramide Assay Enzyme Immunoassay, Lidocaine SMN 10445370 Catalog No 6N319UL

Siemens Healthcare Diagnostics, Inc.
FDA DevicesClass III

Syva Emit Disopyramide Assay Enzyme Immunoassay, Lidocaine SMN 10445370 Catalog No 6N319UL

Out-of-specification sodium azide concentration in Syva Emit Disopyramide Enzyme Immunoassay Calibrator Lot U1. While the assay results were not impacted, the overall health risk to lab technicians due to this issue is low, as exposure is limited by small volumes and a 0.2% post-reconstitution sodium azide concentration, with the worst outcome being mild skin or eye irritation and no serious harm anticipated.

Aug 12, 2026Siemens Healthcare Diagnostics, Inc.
Medical DeviceUSFDA Devices

GE Healthcare Portrait Core Services SW V 1.2.0, REF 5700592. patient monitoring system

GE Medical Systems Information Technologies Inc
FDA DevicesClass II

GE Healthcare Portrait Core Services SW V 1.2.0, REF 5700592. patient monitoring system

A software vulnerability may allow unauthorized persons to gain privileged access to the device, which could result in loss of patient monitoring, missed patient alarms, and/or access to Protected Health Information (PHI).

Aug 12, 2026GE Medical Systems Information Technologies Inc
Medical DeviceUSFDA Devices

GEM Premier 7000 with iQM3 Part Numbers: 00077407508 00077407510 00077415004 00077415008 00077415010 00077430010 Product Description: The GEM Premier 7000 with iQM3 is a portable critical care system for use by health care professionals to rapidly analyze lithium heparinized whole blood samples at the point of health care delivery in a clinical setting and in a central laboratory.

Instrumentation Laboratory
FDA DevicesClass II

GEM Premier 7000 with iQM3 Part Numbers: 00077407508 00077407510 00077415004 00077415008 00077415010 00077430010 Product Description: The GEM Premier 7000 with iQM3 is a portable critical care system for use by health care professionals to rapidly analyze lithium heparinized whole blood samples at the point of health care delivery in a clinical setting and in a central laboratory.

The active ingredient concentration in the lysing bag solution of specific GEM Premier 7000 with iQM3 PAK lots did not meet established manufacturing specifications. The malfunction could result in delayed recognition and management of Co-Oximetry and total bilirubin abnormalities and their sequelae.

Aug 12, 2026Instrumentation Laboratory
Medical DeviceUSFDA Devices

STRYKER AHTO TUBE SET PACKAGING, Catalog Number 0250070600

Stryker Corporation
FDA DevicesClass II

STRYKER AHTO TUBE SET PACKAGING, Catalog Number 0250070600

There has been an increased amount in reported complaints consistently describing leaking from the handpiece during use.

Aug 12, 2026Stryker Corporation
Medical DeviceUSFDA Devices

Halyard convenience kits containing recalled Medline Namic Angiographic Star Off Handle Manifolds. HEART CATH, SELF REGIONAL SELF131-05

AVID Medical, Inc.
FDA DevicesClass I

Halyard convenience kits containing recalled Medline Namic Angiographic Star Off Handle Manifolds. HEART CATH, SELF REGIONAL SELF131-05

Affected kits contain Medline Namic Angiographic Star Off Handle Manifolds, which were recalled by the manufacturer due to presence of particulates within fluid path of the Manifolds. Particulate within the fluid path has the potential to be introduced into blood circulation and become lodged within blood vessels.

Aug 12, 2026AVID Medical, Inc.

Install The Recall File App