Reprocessed Siemens ACUSON AcuNav Diagnostic Ultrasound Catheters: ACUSON AcuNav Ultrasound Catheter, Use on GE Systems 10135910RH; 10043342RH ACUSON AcuNav Ultrasound Catheter, Use on Siemens Systems 10135936RH, 08255790RH
Reprocessed Siemens ACUSON AcuNav Diagnostic Ultrasound Catheters: ACUSON AcuNav Ultrasound Catheter, Use on GE Systems 10135910RH; 10043342RH ACUSON AcuNav Ultrasound Catheter, Use on Siemens Systems 10135936RH, 08255790RH
These lots of reprocessed catheters may contain small particles of residual material. If affected devices are used, there is a risk of inflammatory response, systemic infection, or granulomatous reaction or thrombus reaction which may lead to cerebral or pulmonary embolism, or deep vein thrombosis. Expansion of recall Z-2610/2614-2025
Azurion 7 M12 System Model Numbers: (1)722078, (2)722223, (3)722233; Software Version Number - All versions: R1.X, R2.X, R3.X
Azurion 7 M12 System Model Numbers: (1)722078, (2)722223, (3)722233; Software Version Number - All versions: R1.X, R2.X, R3.X
Under certain conditions, the table may move unexpectedly when the Reset Geometry button is pressed - even when a table lock is active.
Surepulse VS Cap Medium REF: SP-161-A1 component of VS Newborn Heart Rate Monitor
Surepulse VS Cap Medium REF: SP-161-A1 component of VS Newborn Heart Rate Monitor
Retroactively reported; Labeling contains incorrect sizing guide for Cap, a component of the heart rate monitor.
da Vinci 5 Surgeon Console Viewer Display, ASSY, DV5 CONSOLE, IS5000, Part Number: 380730-45
da Vinci 5 Surgeon Console Viewer Display, ASSY, DV5 CONSOLE, IS5000, Part Number: 380730-45
Robotic-assisted surgical system has Viewer Display manufactured with outdated firmware, may result in loss of one display-loss of 3D surgical field (depth perception) but 2D maintained, or loss of both displays-complete visualization loss, without fault, instruments remain active, could lead to instrument contact with tissue, resulting in injury/bleeding; may require alternate surgical modality.
IQon Spectral CT; Product Code (REF): 728332;
IQon Spectral CT; Product Code (REF): 728332;
As part of the CT systems sub assembly, thirty-two (32) fasteners are used to attach the rotor to the bearing within the gantry. One or more of these fasteners may not be torqued to specification. If multiple fasteners are not torqued to specification, the rotor or rotor parts may become unsecured or displaced. While there has been no reported or observed event of expelled parts during gantry rotation, unsecured rotor parts may potentially be expelled.
Medline medical convenience kits packaged as: ) LVAD DRESSING CHANGE TRAY, Kit SKU DM320C; 2) PORT AND IO ACCESS DRESSING KI, Kit SKU DT15780A; 3) PORT-A-CATH DRESSING CHANGE TR, Kit SKU DT16615; 4) LARGE BORE CENTRAL LINE DRSG C, Kit SKU DT19660; 5) CENTRAL LINE DRESSING CHANGE K, Kit SKU DT19665; 6) NEONATAL DRESSING CHANGE KIT, Kit SKU DT21495; 7) NICU CVC DRESSING CHANGE TRAY, Kit SKU DT22510A; 8) DRESSING CHANGE TRAY W/TEG CHG, Kit SKU DYNDC3114B; 9) DRESSING CHANGE KIT, Kit SKU DYNDC3351.
Medline medical convenience kits packaged as: ) LVAD DRESSING CHANGE TRAY, Kit SKU DM320C; 2) PORT AND IO ACCESS DRESSING KI, Kit SKU DT15780A; 3) PORT-A-CATH DRESSING CHANGE TR, Kit SKU DT16615; 4) LARGE BORE CENTRAL LINE DRSG C, Kit SKU DT19660; 5) CENTRAL LINE DRESSING CHANGE K, Kit SKU DT19665; 6) NEONATAL DRESSING CHANGE KIT, Kit SKU DT21495; 7) NICU CVC DRESSING CHANGE TRAY, Kit SKU DT22510A; 8) DRESSING CHANGE TRAY W/TEG CHG, Kit SKU DYNDC3114B; 9) DRESSING CHANGE KIT, Kit SKU DYNDC3351.
Medline Industries, LP is issuing a recall for specific items and lots of Medline Kits containing BD ChloraPrep Triple Swabsticks which BD determined may exhibit an open seal on the packaging of the applicators.
Barco MNA with the HexaVue IP Integration System, Model/Catalog Number: MNA-6x0-H
Barco MNA with the HexaVue IP Integration System, Model/Catalog Number: MNA-6x0-H
This is a sub-recall of event RES 96885. The supplier identified that during their manufacturing process for a limited batch of MNA-6x0 (adapter) components the incorrect configuration file was used.
Brand Name: Leksell GammaPlan Product Name: Radionuclide RT Treatment planning system Software Version: 11.1 Product Description: Leksell GammaPlan¿ is a computer-based system designed for Leksell Gamma Knife¿ treatment planning.
Brand Name: Leksell GammaPlan Product Name: Radionuclide RT Treatment planning system Software Version: 11.1 Product Description: Leksell GammaPlan¿ is a computer-based system designed for Leksell Gamma Knife¿ treatment planning.
Due to an error when defining a new stereotactic reference that users fail to first change an already defined obsolete reference to a pre-plan reference. This may result in a treatment plan that potentially irradiates the incorrect patient location if the error is not detected by users.
Azurion 3 M15 System Model Numbers: (1) 722064, (2) 722222, (3) 722230, (4)722280(OUS only); Software Version Number - All versions: R1.X, R2.X, R3.X
Azurion 3 M15 System Model Numbers: (1) 722064, (2) 722222, (3) 722230, (4)722280(OUS only); Software Version Number - All versions: R1.X, R2.X, R3.X
Under certain conditions, the table may move unexpectedly when the Reset Geometry button is pressed - even when a table lock is active.
ATEC Lateral Navigation Disc Prep Instruments LIF NAV, OSTEOTOME 10mm REF 266-01-000-10-N UDI-DI code: 00190376476179; GMDN 12844 The ATEC Navigation Disc Prep Instruments are intended for use in surgical procedures. These instruments are non-sterile or sterile packaged, re-usable or single-use instruments designed to function with the Medtronic StealthStation System and NavLock Tracker.
ATEC Lateral Navigation Disc Prep Instruments LIF NAV, OSTEOTOME 10mm REF 266-01-000-10-N UDI-DI code: 00190376476179; GMDN 12844 The ATEC Navigation Disc Prep Instruments are intended for use in surgical procedures. These instruments are non-sterile or sterile packaged, re-usable or single-use instruments designed to function with the Medtronic StealthStation System and NavLock Tracker.
Due a design issue where the navigated array connection geometry is incorrect.
Surepulse VS Cap Extra Small REF: SP-159-A1 component of VS Newborn Heart Rate Monitor
Surepulse VS Cap Extra Small REF: SP-159-A1 component of VS Newborn Heart Rate Monitor
Retroactively reported; Labeling contains incorrect sizing guide for Cap, a component of the heart rate monitor.
Medline medical convenience kits packaged as: MERCY CIRCUMCISION TRAY, Kit SKU CIT6135B
Medline medical convenience kits packaged as: MERCY CIRCUMCISION TRAY, Kit SKU CIT6135B
Medline Industries, LP is issuing a recall for specific items and lots of Medline Kits containing BD ChloraPrep Triple Swabsticks which BD determined may exhibit an open seal on the packaging of the applicators.
WB Impression Post Closed Tray incl. guide screw, L 13mm, TAN/POM
WB Impression Post Closed Tray incl. guide screw, L 13mm, TAN/POM
The mix up of the impression caps provided in the package. The provided impression caps are magenta instead of brown.
Medline medical convenience kits packaged as: 1) CANCER SERVICE PORT KIT, Kit SKU DT22710; 2) LINE KIT, Kit SKU DYNDA1857A; 3) PICC REMOVAL KIT, Kit SKU DYNDC1978A; 4) PORT ACCESS TRAY, Kit SKU DYNDC2367; 5) NICU CENTRAL LINE TRAY, Kit SKU DYNDC2407B; 6) CVC DRESSING CHANGE W/ TEG CHG, Kit SKU DYNDC3222A; 7) PICC PROCEDURE PACK, Kit SKU DYNJ59067A; 8) PICC PROCEDURE PACK, Kit SKU PHS950205004B.
Medline medical convenience kits packaged as: 1) CANCER SERVICE PORT KIT, Kit SKU DT22710; 2) LINE KIT, Kit SKU DYNDA1857A; 3) PICC REMOVAL KIT, Kit SKU DYNDC1978A; 4) PORT ACCESS TRAY, Kit SKU DYNDC2367; 5) NICU CENTRAL LINE TRAY, Kit SKU DYNDC2407B; 6) CVC DRESSING CHANGE W/ TEG CHG, Kit SKU DYNDC3222A; 7) PICC PROCEDURE PACK, Kit SKU DYNJ59067A; 8) PICC PROCEDURE PACK, Kit SKU PHS950205004B.
Medline Industries, LP is issuing a recall for specific items and lots of Medline Kits containing BD ChloraPrep Triple Swabsticks which BD determined may exhibit an open seal on the packaging of the applicators.
Halyard TRANSPORT BAG KIT. Kit Code: LIFE0080-01.
Halyard TRANSPORT BAG KIT. Kit Code: LIFE0080-01.
Tyvek bag seal issue which may compromise sterility of the kit.
Brand Name: Leksell GammaPlan Product Name: Radionuclide RT Treatment planning system Software Version: 11,3, 11.4 Product Description: Leksell GammaPlan¿ is a computer-based system designed for Leksell Gamma Knife¿ treatment planning.
Brand Name: Leksell GammaPlan Product Name: Radionuclide RT Treatment planning system Software Version: 11,3, 11.4 Product Description: Leksell GammaPlan¿ is a computer-based system designed for Leksell Gamma Knife¿ treatment planning.
Due to an error when defining a new stereotactic reference that users fail to first change an already defined obsolete reference to a pre-plan reference. This may result in a treatment plan that potentially irradiates the incorrect patient location if the error is not detected by users.
Medline ReNewal Reprocessed ViewFlex Xtra ICE Catheters: ViewFlex Xtra ICE Catheter 9F x 90cm D087031RH 20197344019554¿
Medline ReNewal Reprocessed ViewFlex Xtra ICE Catheters: ViewFlex Xtra ICE Catheter 9F x 90cm D087031RH 20197344019554¿
These lots of reprocessed catheters may contain small particles of residual material. If affected devices are used, there is a risk of inflammatory response, systemic infection, or granulomatous reaction or thrombus reaction which may lead to cerebral or pulmonary embolism, or deep vein thrombosis. Expansion of recall Z-2610/2614-2025
Azurion 5 M12 System Model Numbers: (1)722227, (2)722231; Software Version Number - All versions: R1.X, R2.X, R3.X
Azurion 5 M12 System Model Numbers: (1)722227, (2)722231; Software Version Number - All versions: R1.X, R2.X, R3.X
Under certain conditions, the table may move unexpectedly when the Reset Geometry button is pressed - even when a table lock is active.
Medline medical convenience kits packaged as: BLOOD CULTURE KIT NS, Kit SKU DYNDH2088
Medline medical convenience kits packaged as: BLOOD CULTURE KIT NS, Kit SKU DYNDH2088
Medline Industries, LP is issuing a recall for specific items and lots of Medline Kits containing BD ChloraPrep Triple Swabsticks which BD determined may exhibit an open seal on the packaging of the applicators.
Surepulse VS Cap Large REF: SP-162-A1 component of VS Newborn Heart Rate Monitor
Surepulse VS Cap Large REF: SP-162-A1 component of VS Newborn Heart Rate Monitor
Retroactively reported; Labeling contains incorrect sizing guide for Cap, a component of the heart rate monitor.
Azurion 7 B20 System Model Numbers: (1)722068, (2)722226, (3)722236; Software Version Number - All versions: R1.X, R2.X, R3.X
Azurion 7 B20 System Model Numbers: (1)722068, (2)722226, (3)722236; Software Version Number - All versions: R1.X, R2.X, R3.X
Under certain conditions, the table may move unexpectedly when the Reset Geometry button is pressed - even when a table lock is active.
Reprocessed Biosense Webster SOUNDSTAR eco Diagnostic Ultrasound Catheters: Biosense Webster SOUNDSTAR eco Diagnostic Ultrasound Catheter Use on GE Systems 10439072RH; Biosense Webster SOUNDSTAR eco Diagnostic Ultrasound Catheter Use on Siemens Systems 10438577RH; Biosense Webster SOUNDSTAR eco Diagnostic Ultrasound Catheter, Use on Siemens Systems 10439011RH
Reprocessed Biosense Webster SOUNDSTAR eco Diagnostic Ultrasound Catheters: Biosense Webster SOUNDSTAR eco Diagnostic Ultrasound Catheter Use on GE Systems 10439072RH; Biosense Webster SOUNDSTAR eco Diagnostic Ultrasound Catheter Use on Siemens Systems 10438577RH; Biosense Webster SOUNDSTAR eco Diagnostic Ultrasound Catheter, Use on Siemens Systems 10439011RH
These lots of reprocessed catheters may contain small particles of residual material. If affected devices are used, there is a risk of inflammatory response, systemic infection, or granulomatous reaction or thrombus reaction which may lead to cerebral or pulmonary embolism, or deep vein thrombosis. Expansion of recall Z-2610/2614-2025
Reprocessed Abbott Inquiry Steerable Diagnostic Catheters: Abbott Inquiry Steerable Diagnostic Catheter 10 Elec. 2-5-2mm 81105RH 81172RH; Abbott Inquiry Steerable Diagnostic Catheter 20 Elec. 2-10-2mm 81202RH; Abbott Inquiry Steerable Diagnostic Catheter 4 Elec. 5mm 81483RH; Inquiry Steerable Diagnostic Catheter 10 Elec. 2-5-2mm 81102RH 81104RH 81174RH 81531RH 81532RH; Inquiry Steerable Diagnostic Catheter 10 Elec. 5mm 81107RH; Inquiry Steerable Diagnostic Catheter 4 Elec. 2-5-2mm 81402RH 81404RH 81405RH 81474RH; Inquiry Steerable Diagnostic Catheter 4 Elec. 5mm 81473RH
Reprocessed Abbott Inquiry Steerable Diagnostic Catheters: Abbott Inquiry Steerable Diagnostic Catheter 10 Elec. 2-5-2mm 81105RH 81172RH; Abbott Inquiry Steerable Diagnostic Catheter 20 Elec. 2-10-2mm 81202RH; Abbott Inquiry Steerable Diagnostic Catheter 4 Elec. 5mm 81483RH; Inquiry Steerable Diagnostic Catheter 10 Elec. 2-5-2mm 81102RH 81104RH 81174RH 81531RH 81532RH; Inquiry Steerable Diagnostic Catheter 10 Elec. 5mm 81107RH; Inquiry Steerable Diagnostic Catheter 4 Elec. 2-5-2mm 81402RH 81404RH 81405RH 81474RH; Inquiry Steerable Diagnostic Catheter 4 Elec. 5mm 81473RH
These lots of reprocessed catheters may contain small particles of residual material. If affected devices are used, there is a risk of inflammatory response, systemic infection, or granulomatous reaction or thrombus reaction which may lead to cerebral or pulmonary embolism, or deep vein thrombosis. Expansion of recall Z-2610/2614-2025
Spectral CT 7500 on Rails; Product Code (REF): 728334;
Spectral CT 7500 on Rails; Product Code (REF): 728334;
As part of the CT systems sub assembly, thirty-two (32) fasteners are used to attach the rotor to the bearing within the gantry. One or more of these fasteners may not be torqued to specification. If multiple fasteners are not torqued to specification, the rotor or rotor parts may become unsecured or displaced. While there has been no reported or observed event of expelled parts during gantry rotation, unsecured rotor parts may potentially be expelled.