Dispositifs Médicaux Recalls

Defective surgical instruments, diagnostic equipment, and health device recalls.

Showing 24 of 2,119 results
Medical DeviceUSFDA Devices

PhaseOne Antimicrobial Solution, Model/Catalog Number: 15050

Oculus Technologies of Mexico, S.A. de C.V.
FDA DevicesClass II

PhaseOne Antimicrobial Solution, Model/Catalog Number: 15050

The recall is being conducted due to corrosion of the internal metallic spring within the sprayer component. This condition is caused by material incompatibility between the product solution and the stainless steel spring and may result in visible discoloration and the presence of trace levels of metallic elements (including iron, chromium, and nickel) in the solution during use.

Jun 10, 2026Oculus Technologies of Mexico, S.A. de C.V.
Medical DeviceUSFDA Devices

ARTIS pheno, Model 10849000. interventional fluoroscopic x-ray system

Siemens Medical Solutions USA, Inc
FDA DevicesClass II

ARTIS pheno, Model 10849000. interventional fluoroscopic x-ray system

During patient examinations, the system may sporadically display a 0 x-ray dose administered to the patient. This behavior has only been observed during fluoroscopy and/or single-frame acquisitions. Despite the reported x-ray dose showing 0, an actual x-ray dose is applied to the patient.

Jun 10, 2026Siemens Medical Solutions USA, Inc
Medical DeviceUSFDA Devices

LVP software of the Ivenix Infusion System (IIS); Product Code LVP-SW-0005.

Fresenius Kabi USA, LLC
FDA DevicesClass I

LVP software of the Ivenix Infusion System (IIS); Product Code LVP-SW-0005.

Potential software anomaly that can cause the pump to report a false battery-health value (typically 69%) and trigger a battery-depletion alarm that will shut down the pump unless it is reconnected to AC mains power.

Jun 10, 2026Fresenius Kabi USA, LLC
Medical DeviceUSFDA Devices

BD¿Spinal Tray with BD¿Whitacre Needle 25 G x 3.5 in.; lidocaine HCL (1%), 5 mL, bupivacaine HCL (0.75%) with dextrose (8.25%), 2 mL (marcaine). Catalog Numbers: 405637, 405707.

Becton Dickinson & Company
FDA DevicesClass I

BD¿Spinal Tray with BD¿Whitacre Needle 25 G x 3.5 in.; lidocaine HCL (1%), 5 mL, bupivacaine HCL (0.75%) with dextrose (8.25%), 2 mL (marcaine). Catalog Numbers: 405637, 405707.

This is a sub-recall of a product recall from Huons Co, Ltd., the manufacturer of Bupivacaine Hydrochloride in Dextrose Injection, USP. The recall is due to quality issues identified during an FDA manufacturing facility inspection, citing specific quality deficiencies related to acceptance testing.

Jun 10, 2026Becton Dickinson & Company
Medical DeviceUSFDA Devices

BD Pyxis MedBank Tower REF: 1145-00 Medication cabinet

CareFusion 303, Inc.
FDA DevicesClass II

BD Pyxis MedBank Tower REF: 1145-00 Medication cabinet

Fingerprint scanner may overheat to a temperature to cause 1st degree burn.

Jun 10, 2026CareFusion 303, Inc.
Medical DeviceUSFDA Devices

Brand Name: Da Vinci 5 Product Name: ASSY,DV5 TOWER,IS5000 Model/Catalog Number: 380746 Software Version: N/A Product Description: Preface: This report under 21 CFR 806.10 is being submitted for the dV5 system tower, as the NIR Handheld Camera or SOCK is developed and integrated as part of the dV5 system. The affected component of the dV5 system tower is the NIR handheld camera, and is supplied by Schoelly as the manufacturer. Therefore, the product description in this report references the NIR handheld camera system. Product Description: The NIR handheld camera system is compatible for use with the da Vinci¿ 5 system to aid in surgery. The components of the NIR handheld camera system include a camera control unit and a light source, NIR handheld camera, and additional components that together, connect to the Tower of the da Vinci 5 system. When setting up the da Vinci 5 system, the image from the NIR handheld camera system is displayed on the Tower monitor. Component: Yes, the SOCK is the component and integrated into the dV5 system

Intuitive Surgical, Inc.
FDA DevicesClass II

Brand Name: Da Vinci 5 Product Name: ASSY,DV5 TOWER,IS5000 Model/Catalog Number: 380746 Software Version: N/A Product Description: Preface: This report under 21 CFR 806.10 is being submitted for the dV5 system tower, as the NIR Handheld Camera or SOCK is developed and integrated as part of the dV5 system. The affected component of the dV5 system tower is the NIR handheld camera, and is supplied by Schoelly as the manufacturer. Therefore, the product description in this report references the NIR handheld camera system. Product Description: The NIR handheld camera system is compatible for use with the da Vinci¿ 5 system to aid in surgery. The components of the NIR handheld camera system include a camera control unit and a light source, NIR handheld camera, and additional components that together, connect to the Tower of the da Vinci 5 system. When setting up the da Vinci 5 system, the image from the NIR handheld camera system is displayed on the Tower monitor. Component: Yes, the SOCK is the component and integrated into the dV5 system

Due to unintentionally activated near infrared handheld camera when attempting to turn off illumination during normal clinical workflow transitions, particularly when switching from the handheld camera to the robotic endoscope.

Jun 10, 2026Intuitive Surgical, Inc.
Medical DeviceUSFDA Devices

Brand Name: B. BRAUN MEDICAL INC. Product Name: SESK UPMC DOUBLE CATHETER TRAY Model/Catalog Number: 530134 Software Version: N/A Product Description: SESK UPMC DOUBLE CATHETER TRAY Component: No

B Braun Medical Inc
FDA DevicesClass II

Brand Name: B. BRAUN MEDICAL INC. Product Name: SESK UPMC DOUBLE CATHETER TRAY Model/Catalog Number: 530134 Software Version: N/A Product Description: SESK UPMC DOUBLE CATHETER TRAY Component: No

B. Braun was notified by our supplier, Ferndale Laboratories, Inc., the manufacturer of MASTISOL¿ Liquid Adhesive, that they have issued a voluntary recall due to potential cracking of the butyrate tubing (outside tube), which renders the product unusable.

Jun 10, 2026B Braun Medical Inc
Medical DeviceUSFDA Devices

Spinocan Spinal Needle procedure kits: Material Description (Material Number): Spinocan 26 Ga. x 3-1/2 in. (90 mm), Bupivacaine 0.75% with Dextrose 8.25% Tray (Kit) (333201); Spinocan 25 Ga. x 3-1/2 in. (90 mm), Bupivacaine 0.75% with Dextrose 8.25% Tray (Kit) (333211); Spinocan 22 Ga. x 3-1/2 in. (90 mm), Bupivacaine 0.75% with Dextrose 8.25% Tray (Kit) (333231)

B Braun Medical Inc
FDA DevicesClass I

Spinocan Spinal Needle procedure kits: Material Description (Material Number): Spinocan 26 Ga. x 3-1/2 in. (90 mm), Bupivacaine 0.75% with Dextrose 8.25% Tray (Kit) (333201); Spinocan 25 Ga. x 3-1/2 in. (90 mm), Bupivacaine 0.75% with Dextrose 8.25% Tray (Kit) (333211); Spinocan 22 Ga. x 3-1/2 in. (90 mm), Bupivacaine 0.75% with Dextrose 8.25% Tray (Kit) (333231)

These procedure kits contain Bupivacaine Hydrochloride in Dextrose Injection, USP. The manufacturer of the Bupivacaine, Huon Co, Ltd., has issued a voluntary recall due to potential quality issues identified during a recent FDA manufacturing facility inspection.

Jun 10, 2026B Braun Medical Inc
Medical DeviceUSFDA Devices

DeRoyal Industries Inc. Ref 46-406, Covaderm Plus, Vascular Access Dressing 6"x6" (15cmx15cm)

DeRoyal Industries Inc
FDA DevicesClass II

DeRoyal Industries Inc. Ref 46-406, Covaderm Plus, Vascular Access Dressing 6"x6" (15cmx15cm)

Sterile wound dressing, lacks sterility assurance

Jun 10, 2026DeRoyal Industries Inc
Medical DeviceUSFDA Devices

Brand Name: B. BRAUN MEDICAL INC. Product Name: CESK HARRIS METHODIST Model/Catalog Number: 555498 Software Version: N/A Product Description: CESK HARRIS METHODIST Component: No

B Braun Medical Inc
FDA DevicesClass II

Brand Name: B. BRAUN MEDICAL INC. Product Name: CESK HARRIS METHODIST Model/Catalog Number: 555498 Software Version: N/A Product Description: CESK HARRIS METHODIST Component: No

B. Braun was notified by our supplier, Ferndale Laboratories, Inc., the manufacturer of MASTISOL¿ Liquid Adhesive, that they have issued a voluntary recall due to potential cracking of the butyrate tubing (outside tube), which renders the product unusable.

Jun 10, 2026B Braun Medical Inc
Medical DeviceUSFDA Devices

TITANIUM/FLUOROPLASTIC PISTON 0.6MM DIA X 3.75MM L Model/Catalog Number: 409-375 Product Description: Stapes Prosthesis

Grace Medical, Inc.
FDA DevicesClass II

TITANIUM/FLUOROPLASTIC PISTON 0.6MM DIA X 3.75MM L Model/Catalog Number: 409-375 Product Description: Stapes Prosthesis

Due to incorrect functional length on device labeling.

Jun 10, 2026Grace Medical, Inc.
Medical DeviceUSFDA Devices

Neptune Smart Docking Station (120V), Catalog Number 0770-100-000, part of the Neptune Waste Management System

Stryker Corporation
FDA DevicesClass II

Neptune Smart Docking Station (120V), Catalog Number 0770-100-000, part of the Neptune Waste Management System

It has been identified that the impacted docking station (SN 2521008873) was not product released from manufacturing and may not have completed required testing prior to being shipped to your facility. There is a potential risk of electrical shock due to the device s safety testing being unverifiable.

Jun 10, 2026Stryker Corporation
Medical DeviceUSFDA Devices

Brand Name: Exacta Mix Product Name: Vented Micro-Volume Inlet Model/Catalog Number: H938175 Product Description: Tubing sets with push-on connector on one end (to attach to the Fluid Selector Valve) and a spike or other appropriate connector on the opposite end to attach the source container.

Baxter Healthcare Corporation
FDA DevicesClass II

Brand Name: Exacta Mix Product Name: Vented Micro-Volume Inlet Model/Catalog Number: H938175 Product Description: Tubing sets with push-on connector on one end (to attach to the Fluid Selector Valve) and a spike or other appropriate connector on the opposite end to attach the source container.

Affected lots may contain incorrect 0.8-micron filters. Use of a 0.8-micron filter in place of the validated 3-micron filter may lead to reduced flow efficiency, incomplete or slower transfers of ingredients, or system alarms. This issue may lead to clinical effects such as electrolyte imbalance, metabolic instability, delayed recovery, etc.

Jun 10, 2026Baxter Healthcare Corporation
Medical DeviceUSFDA Devices

BD¿Spinal Tray with BD¿Whitacre Needle 25 G x 3.5 in.; lidocaine HCL (1%), 5 mL, bupivacaine HCL (0.75%) with dextrose (8.25%), 2 mL (marcaine). Catalog Numbers: 400866, 405672, 405673, 405674, 405675, 405709, 405721, 405723, 406704.

Becton Dickinson & Company
FDA DevicesClass I

BD¿Spinal Tray with BD¿Whitacre Needle 25 G x 3.5 in.; lidocaine HCL (1%), 5 mL, bupivacaine HCL (0.75%) with dextrose (8.25%), 2 mL (marcaine). Catalog Numbers: 400866, 405672, 405673, 405674, 405675, 405709, 405721, 405723, 406704.

This is a sub-recall of a product recall from Huons Co, Ltd., the manufacturer of Bupivacaine Hydrochloride in Dextrose Injection, USP. The recall is due to quality issues identified during an FDA manufacturing facility inspection, citing specific quality deficiencies related to acceptance testing.

Jun 10, 2026Becton Dickinson & Company
Medical DeviceUSFDA Devices

Philips Azurion 3M12, Model Numbers: 722063, 722221 with Software release R2.2.0, R2.2.1, R2.2.3, R2.2.5 and R2.2.6 with the Roadmap Pro Software key

PHILIPS MEDICAL SYSTEMS NEDERLAND B.V.
FDA DevicesClass II

Philips Azurion 3M12, Model Numbers: 722063, 722221 with Software release R2.2.0, R2.2.1, R2.2.3, R2.2.5 and R2.2.6 with the Roadmap Pro Software key

During the device phase of Roadmap Pro, a user may experience a dark image that is not clinically usable. The dark image may result after the user performs a pedal tap (shortly touching the footswitch pedal without generating an Xray image). The pedal tap may cause a dark image with the next fluoroscopy run.

Jun 10, 2026PHILIPS MEDICAL SYSTEMS NEDERLAND B.V.
Medical DeviceUSFDA Devices

Design Options Spinal Tray Spinal Needle Anesthesia procedure kits: Material Description (Material Number): SSK H M C 20061890 (560074), SSK S C H (560214), SSK BJC H S (ORIGINAL CUST) (560272), SSK CA P M C (ORIGINAL CUST) (560327), SSK T M H (560394), SSK S O 20070208 (560428), SSK L G H (ORIGINAL CUST) (560462), SSK H M H (560465), SSK BUPIVACAINE TRAY 2068824 (560476), SSK K F H (560497), SSK T J U H (560513), SSK O M C (560521), SSK CUSTOM SPINAL TRAY (560523), SSK O R M C (560533), SSK B S H S 20115122 (560538), SSK M M (560572), SSK M S 27GA PENCAN SPINAL TRAY (560580), SSK S T H & C (560584), SSK U C (560587), SSK P25BKG (560603), SSK P24BKG (560606), SSK S25BKG (560607), SSK M C - BUPIVACAINE TRAY (560609), SSK T M C (560613), SSK PENCIL POINT SPINAL TRAY (560619), SSK E O & S H-SPINAL (560621), SSK BSW SPINAL TRAY (560628), SSK M C OB DEPT - SPINAL (560645), SSK B H M (560646), SSK M G M C (560647), SSK S M H (560648), SSK H H S (560660), O S U M C SPINAL TRAY SSK (560667), A M C, SSK (560670), S B H - SPINAL TRAY SSK (560672);

B Braun Medical Inc
FDA DevicesClass I

Design Options Spinal Tray Spinal Needle Anesthesia procedure kits: Material Description (Material Number): SSK H M C 20061890 (560074), SSK S C H (560214), SSK BJC H S (ORIGINAL CUST) (560272), SSK CA P M C (ORIGINAL CUST) (560327), SSK T M H (560394), SSK S O 20070208 (560428), SSK L G H (ORIGINAL CUST) (560462), SSK H M H (560465), SSK BUPIVACAINE TRAY 2068824 (560476), SSK K F H (560497), SSK T J U H (560513), SSK O M C (560521), SSK CUSTOM SPINAL TRAY (560523), SSK O R M C (560533), SSK B S H S 20115122 (560538), SSK M M (560572), SSK M S 27GA PENCAN SPINAL TRAY (560580), SSK S T H & C (560584), SSK U C (560587), SSK P25BKG (560603), SSK P24BKG (560606), SSK S25BKG (560607), SSK M C - BUPIVACAINE TRAY (560609), SSK T M C (560613), SSK PENCIL POINT SPINAL TRAY (560619), SSK E O & S H-SPINAL (560621), SSK BSW SPINAL TRAY (560628), SSK M C OB DEPT - SPINAL (560645), SSK B H M (560646), SSK M G M C (560647), SSK S M H (560648), SSK H H S (560660), O S U M C SPINAL TRAY SSK (560667), A M C, SSK (560670), S B H - SPINAL TRAY SSK (560672);

These procedure kits contain Bupivacaine Hydrochloride in Dextrose Injection, USP. The manufacturer of the Bupivacaine, Huon Co, Ltd., has issued a voluntary recall due to potential quality issues identified during a recent FDA manufacturing facility inspection.

Jun 10, 2026B Braun Medical Inc
Medical DeviceUSFDA Devices

Covidien Mon-a-Therm General Purpose Temperature Probe REF: 90044

Covidien LLC
FDA DevicesClass II

Covidien Mon-a-Therm General Purpose Temperature Probe REF: 90044

Temperature probe devices lack FDA clearance.

Jun 10, 2026Covidien LLC
Medical DeviceUSFDA Devices

BD Pyxis MedStation ES REF: 323 Medication cabinet

CareFusion 303, Inc.
FDA DevicesClass II

BD Pyxis MedStation ES REF: 323 Medication cabinet

Fingerprint scanner may overheat to a temperature to cause 1st degree burn.

Jun 10, 2026CareFusion 303, Inc.
Medical DeviceUSFDA Devices

BD¿Spinal Tray with BD¿Quincke Needle 25 G x 3.5 in.; lidocaine HCL (1%), 5 mL, bupivacaine HCL (0.75%) with dextrose (8.25%), 2 mL (marcaine). Catalog Numbers: 405621, 405735.

Becton Dickinson & Company
FDA DevicesClass I

BD¿Spinal Tray with BD¿Quincke Needle 25 G x 3.5 in.; lidocaine HCL (1%), 5 mL, bupivacaine HCL (0.75%) with dextrose (8.25%), 2 mL (marcaine). Catalog Numbers: 405621, 405735.

This is a sub-recall of a product recall from Huons Co, Ltd., the manufacturer of Bupivacaine Hydrochloride in Dextrose Injection, USP. The recall is due to quality issues identified during an FDA manufacturing facility inspection, citing specific quality deficiencies related to acceptance testing.

Jun 10, 2026Becton Dickinson & Company
Medical DeviceUSFDA Devices

Atlan A350. Model Number: 8211500. anesthesia workstation

Draeger, Inc.
FDA DevicesClass I

Atlan A350. Model Number: 8211500. anesthesia workstation

The Atlan anesthesia workstation either indicated a failure of the piston ventilator before use or suffered a failure of the mechanical ventilation during use.

Jun 10, 2026Draeger, Inc.
Medical DeviceUSFDA Devices

Philips Azurion 7M20, Model Numbers: 722079, 722224 with Software release R2.2.0, R2.2.1, R2.2.3, R2.2.5 and R2.2.6 with the Roadmap Pro Software key

PHILIPS MEDICAL SYSTEMS NEDERLAND B.V.
FDA DevicesClass II

Philips Azurion 7M20, Model Numbers: 722079, 722224 with Software release R2.2.0, R2.2.1, R2.2.3, R2.2.5 and R2.2.6 with the Roadmap Pro Software key

During the device phase of Roadmap Pro, a user may experience a dark image that is not clinically usable. The dark image may result after the user performs a pedal tap (shortly touching the footswitch pedal without generating an Xray image). The pedal tap may cause a dark image with the next fluoroscopy run.

Jun 10, 2026PHILIPS MEDICAL SYSTEMS NEDERLAND B.V.
Medical DeviceUSFDA Devices

ARTIS Icono biplane, floor and ceiling.: ARTIS icono biplane Model 11327600. ARTIS icono ceiling Model 11328100. ARTIS icono floor Model 11327700. interventional fluoroscopic x-ray system

Siemens Medical Solutions USA, Inc
FDA DevicesClass II

ARTIS Icono biplane, floor and ceiling.: ARTIS icono biplane Model 11327600. ARTIS icono ceiling Model 11328100. ARTIS icono floor Model 11327700. interventional fluoroscopic x-ray system

During patient examinations, the system may sporadically display a 0 x-ray dose administered to the patient. This behavior has only been observed during fluoroscopy and/or single-frame acquisitions. Despite the reported x-ray dose showing 0, an actual x-ray dose is applied to the patient.

Jun 10, 2026Siemens Medical Solutions USA, Inc
Medical DeviceUSFDA Devices

Philips Azurion 5M12, Model Numbers: 722227 with Software release R2.2.0, R2.2.1, R2.2.3, R2.2.5 and R2.2.6 with the Roadmap Pro Software key

PHILIPS MEDICAL SYSTEMS NEDERLAND B.V.
FDA DevicesClass II

Philips Azurion 5M12, Model Numbers: 722227 with Software release R2.2.0, R2.2.1, R2.2.3, R2.2.5 and R2.2.6 with the Roadmap Pro Software key

During the device phase of Roadmap Pro, a user may experience a dark image that is not clinically usable. The dark image may result after the user performs a pedal tap (shortly touching the footswitch pedal without generating an Xray image). The pedal tap may cause a dark image with the next fluoroscopy run.

Jun 10, 2026PHILIPS MEDICAL SYSTEMS NEDERLAND B.V.
Medical DeviceUSFDA Devices

Brand Name: B. BRAUN MEDICAL INC. Product Name: CESK SHANDS JACKSONVILLE 20055717 Model/Catalog Number: 555884 Software Version: N/A Product Description: CESK SHANDS JACKSONVILLE 20055717 Component: No

B Braun Medical Inc
FDA DevicesClass II

Brand Name: B. BRAUN MEDICAL INC. Product Name: CESK SHANDS JACKSONVILLE 20055717 Model/Catalog Number: 555884 Software Version: N/A Product Description: CESK SHANDS JACKSONVILLE 20055717 Component: No

B. Braun was notified by our supplier, Ferndale Laboratories, Inc., the manufacturer of MASTISOL¿ Liquid Adhesive, that they have issued a voluntary recall due to potential cracking of the butyrate tubing (outside tube), which renders the product unusable.

Jun 10, 2026B Braun Medical Inc