Medical DeviceUSFDA Devices

Ingenuity CT CT5000 Ingenuity Plus CT5000 Ingenuity Pro CT5000 Ingenuity Premium Ingenuity CT Upgrades Ingenuity CT China Ingenuity Core 128 Elite Brazil

PHILIPS MEDICAL SYSTEMS
FDA DevicesClass II

Ingenuity CT CT5000 Ingenuity Plus CT5000 Ingenuity Pro CT5000 Ingenuity Premium Ingenuity CT Upgrades Ingenuity CT China Ingenuity Core 128 Elite Brazil

The clinical CT scan may not automatically trigger after the Bolus Tracking scan and may need to be triggered manually. Additional Bolus Tracking shots may occur. This may result in the clinical acquisition being inadequate for diagnosis, causing a potential for patient rescan and receiving additional radiation.

Aug 5, 2026PHILIPS MEDICAL SYSTEMS
Medical DeviceUSFDA Devices

EOPA 3D Arterial Cannula DIL TIP 22FR, intended for use with cardiopulmonary bypass as an arterial return cannula, Model Number 78222

Medtronic Perfusion Systems
FDA DevicesClass II

EOPA 3D Arterial Cannula DIL TIP 22FR, intended for use with cardiopulmonary bypass as an arterial return cannula, Model Number 78222

Pinhole leaks may occur in the wire-wound body during cardiopulmonary bypass. Potential risks associated with this condition may include hypovolemia, vessel laceration or perforation, hypotension, ischemia, and organ dysfunction.

Aug 5, 2026Medtronic Perfusion Systems
Medical DeviceUSFDA Devices

OsteoBallast, 45 x 17.5 mm (SeaSpine Brand), REF: 56800095. Ballast, 45 x 17.5 mm (IsoTis Brand), REF: 02-8000-095

IsoTis OrthoBiologics, Inc.
FDA DevicesClass II

OsteoBallast, 45 x 17.5 mm (SeaSpine Brand), REF: 56800095. Ballast, 45 x 17.5 mm (IsoTis Brand), REF: 02-8000-095

Demineralized bone matrix (DBM) in resorbable mesh indicated for use with autograft as a bone graft extender in the posterolateral spine and pelvis, were filled with approx. 4.5 cc DBM (fill for 45 ¿ 11 mm configuration) instead of approx. 7.5 cc DBM (fill for 45 ¿ 17.5 mm configuration), which may lead to delayed fusion, incomplete fusion, pseudarthrosis, or lack of bone ingrowth.

Aug 5, 2026IsoTis OrthoBiologics, Inc.
Medical DeviceUSFDA Devices

Stryker Hoffmann II Connecting Rod Micro 3 x 120mm. Catalog Number: 50796120.

Stryker GmbH
FDA DevicesClass II

Stryker Hoffmann II Connecting Rod Micro 3 x 120mm. Catalog Number: 50796120.

Potential cracking of the Hoffmann II Carbon Connecting Rods following cleaning and sterilization.

Aug 5, 2026Stryker GmbH
Medical DeviceUSFDA Devices

Permobil M3 Corpus Power Wheelchair with Heavy Duty Shock REF:120031, Model version 3

Permobil Inc
FDA DevicesClass II

Permobil M3 Corpus Power Wheelchair with Heavy Duty Shock REF:120031, Model version 3

This recall has been reported retroactively. The power wheelchair firmware lacks a speed restriction to maintain stability when the seat lift exceeds 50 mm, which may cause the user to fall from the wheelchair or the wheelchair to tip over,

Aug 5, 2026Permobil Inc
Medical DeviceUSFDA Devices

Stryker Hoffmann II Connecting Rod Micro 3 x 40mm. Catalog Number: 50796040.

Stryker GmbH
FDA DevicesClass II

Stryker Hoffmann II Connecting Rod Micro 3 x 40mm. Catalog Number: 50796040.

Potential cracking of the Hoffmann II Carbon Connecting Rods following cleaning and sterilization.

Aug 5, 2026Stryker GmbH
Medical DeviceUSFDA Devices

EOPA Elongated One-Piece Arterial Cannula BLUNT 22FR, intended for use with cardiopulmonary bypass as an arterial return cannula, Model Number 77422

Medtronic Perfusion Systems
FDA DevicesClass II

EOPA Elongated One-Piece Arterial Cannula BLUNT 22FR, intended for use with cardiopulmonary bypass as an arterial return cannula, Model Number 77422

Pinhole leaks may occur in the wire-wound body during cardiopulmonary bypass. Potential risks associated with this condition may include hypovolemia, vessel laceration or perforation, hypotension, ischemia, and organ dysfunction.

Aug 5, 2026Medtronic Perfusion Systems
Medical DeviceUSFDA Devices

AMS ALIGNED MEDICAL SOLUTIONS medical convenience kits labeled as: 1) Dr Fred Chiu Single Shot Epi Tray - Rx, Part Number AMS1095(E ; 2) Single Shot Epidural Tray - RX, Part Number AMS11296A; 3) Nerve Block Tray - RX, Part Number AMS11314A; 4) Epidural Tray - RX, Part Number AMS11910A; 5) Nerve Block Tray - RX, Part Number AMS12171; 6) Single Shot Epidural Tray - RX, Part Number AMS12219A; 7) Universal Block Tray - RX, Part Number AMS12381B.

Windstone Medical Packaging, Inc.
FDA DevicesClass II

AMS ALIGNED MEDICAL SOLUTIONS medical convenience kits labeled as: 1) Dr Fred Chiu Single Shot Epi Tray - Rx, Part Number AMS1095(E ; 2) Single Shot Epidural Tray - RX, Part Number AMS11296A; 3) Nerve Block Tray - RX, Part Number AMS11314A; 4) Epidural Tray - RX, Part Number AMS11910A; 5) Nerve Block Tray - RX, Part Number AMS12171; 6) Single Shot Epidural Tray - RX, Part Number AMS12219A; 7) Universal Block Tray - RX, Part Number AMS12381B.

Windstone Medical Packaging issued a recall for specific item(s) and lot(s) of Aligned Medical Solutions (AMS) convenience kits containing Elevaris Lidocaine HCl injection USP. Elevaris Medical Devices Inc. recalled the Lidocaine HCl injection USP due to supplier quality issues.

Aug 5, 2026Windstone Medical Packaging, Inc.
Medical DeviceUSFDA Devices

AMS ALIGNED MEDICAL SOLUTIONS medical convenience kits labeled as: 1) Loop Recorder Pack 2 -RX, Part Number AMS10164; 2) NY Tray - RX, Part Number AMS10276A; 3) NYC Tray - RX, Part Number AMS10281B; 4) Vein Pack - RX, Part Number AMS11398C; 5) Radiology Tray-RX, Part Number AMS1217A; 6) Custom Pack - RX, Part Number AMS12757B; 7) Biopsy Tray w/Lidocaine - RX, Part Number AMS13700; 8) Arthrogram Tray - RX, Part Number AMS13755A; 9) Myelogram Tray - RX, Part Number AMS14805A; 10) Arthrogram Tray - RX, Part Number AMS15071A; 11) Vein Pack - RX, Part Number AMS15270; 12) Myelogram Tray - RX, Part Number AMS15298; 13) Loop Pack - RX, Part Number AMS15643; 14) Basic Biopsy Tray - RX, Part Number AMS15662A; 15) Pain Pack -RX, Part Number AMS17021; 16) Pain Tray -RX, Part Number AMS17817; 17) Vasectomy Pack - RX, Part Number AMS18226; 18) Arthrogram Tray- RX, Part Number AMS2886(A; 19) Custom Pack - RX, Part Number AMS3081C; 20) Basic Procedure Pack - RX, Part Number AMS5497; 21) Basic Pack - RX, Part Number AMS8130C; 22) Supply Kit - RX, Part Number AMS9521A; 23) Maximal Sterile Barrier Vascular Access Procedure Kit - RX, Part Number VK0003MB.

Windstone Medical Packaging, Inc.
FDA DevicesClass II

AMS ALIGNED MEDICAL SOLUTIONS medical convenience kits labeled as: 1) Loop Recorder Pack 2 -RX, Part Number AMS10164; 2) NY Tray - RX, Part Number AMS10276A; 3) NYC Tray - RX, Part Number AMS10281B; 4) Vein Pack - RX, Part Number AMS11398C; 5) Radiology Tray-RX, Part Number AMS1217A; 6) Custom Pack - RX, Part Number AMS12757B; 7) Biopsy Tray w/Lidocaine - RX, Part Number AMS13700; 8) Arthrogram Tray - RX, Part Number AMS13755A; 9) Myelogram Tray - RX, Part Number AMS14805A; 10) Arthrogram Tray - RX, Part Number AMS15071A; 11) Vein Pack - RX, Part Number AMS15270; 12) Myelogram Tray - RX, Part Number AMS15298; 13) Loop Pack - RX, Part Number AMS15643; 14) Basic Biopsy Tray - RX, Part Number AMS15662A; 15) Pain Pack -RX, Part Number AMS17021; 16) Pain Tray -RX, Part Number AMS17817; 17) Vasectomy Pack - RX, Part Number AMS18226; 18) Arthrogram Tray- RX, Part Number AMS2886(A; 19) Custom Pack - RX, Part Number AMS3081C; 20) Basic Procedure Pack - RX, Part Number AMS5497; 21) Basic Pack - RX, Part Number AMS8130C; 22) Supply Kit - RX, Part Number AMS9521A; 23) Maximal Sterile Barrier Vascular Access Procedure Kit - RX, Part Number VK0003MB.

Windstone Medical Packaging issued a recall for specific item(s) and lot(s) of Aligned Medical Solutions (AMS) convenience kits containing Elevaris Lidocaine HCl injection USP. Elevaris Medical Devices Inc. recalled the Lidocaine HCl injection USP due to supplier quality issues.

Aug 5, 2026Windstone Medical Packaging, Inc.
Medical DeviceUSFDA Devices

Resmed Astral 100/150 Resmed Astral 100/50 is a ventilator system that provides continuous or intermittent ventilatory support for patients weighing more than 11lb (5kg) who require mechanical ventilation.

ResMed Ltd.
FDA DevicesClass I

Resmed Astral 100/150 Resmed Astral 100/50 is a ventilator system that provides continuous or intermittent ventilatory support for patients weighing more than 11lb (5kg) who require mechanical ventilation.

Due to a Supercapacitor electrolyte leakage on Printed Circuit Board Assembly (PCBA) may damage the charger chip, causing fail-safe state and interruption of ventilation therapy.

Aug 5, 2026ResMed Ltd.
Medical DeviceUSFDA Devices

AMS ALIGNED MEDICAL SOLUTIONS medical convenience kits labeled as: 1) ENT Pack, Pack Number AMS12206; 2) ENT Pack, Pack Number AMS15517; 3) ENT Facial Pack, Pack Number AMS15863A.

Windstone Medical Packaging, Inc.
FDA DevicesClass II

AMS ALIGNED MEDICAL SOLUTIONS medical convenience kits labeled as: 1) ENT Pack, Pack Number AMS12206; 2) ENT Pack, Pack Number AMS15517; 3) ENT Facial Pack, Pack Number AMS15863A.

The recall notice was initiated due to a Medicom Urgent Medical Device Recall. Medicom is recalling specific lots of Ritmed¿ Neurological Sponges Non-Sterile Models 55992C to 55998C due to potential for unexpected variability of endotoxin levels on the products.

Aug 5, 2026Windstone Medical Packaging, Inc.
Medical DeviceUSFDA Devices

M5 Corpus Power Wheelchair REF,120032

Permobil Inc
FDA DevicesClass II

M5 Corpus Power Wheelchair REF,120032

This recall is being reported retroactively. Power Platform firmware is missing specific drive inhibit logic. This issue may allow the chair to drive under restricted conditions, and may create an unstable condition in certain circumstances.

Aug 5, 2026Permobil Inc
Medical DeviceUSFDA Devices

Brand Name: GEM Premier 5000 Product Name: GEM Premier 5000 Model/Catalog Number: 00024019255 portable blood analyzer system

Instrumentation Laboratory
FDA DevicesClass II

Brand Name: GEM Premier 5000 Product Name: GEM Premier 5000 Model/Catalog Number: 00024019255 portable blood analyzer system

Potential for Bar Code Reader (BCR) wands, used with the GEM Premier 5000 and GEM Premier 7000 systems, to assign patient results to an incorrect patient ID.

Aug 5, 2026Instrumentation Laboratory
Medical DeviceUSFDA Devices

Brand Name: GEM Premier 5000 Product Name: GEM Premier 5000 Model/Catalog Number: 00024019255 Portable blood analyzer system

Instrumentation Laboratory
FDA DevicesClass II

Brand Name: GEM Premier 5000 Product Name: GEM Premier 5000 Model/Catalog Number: 00024019255 Portable blood analyzer system

Potential for Bar Code Reader (BCR) wands, used with the GEM Premier 5000 and GEM Premier 7000 systems, to assign patient results to an incorrect patient ID.

Aug 5, 2026Instrumentation Laboratory
Medical DeviceUSFDA Devices

Power Over Fiber Base Module

Terex Utilities
FDA DevicesClass II

Power Over Fiber Base Module

Device not certified - no laser product report was filed with CDRH prior to distribution. Product label incorrectly states device is "Class IV", although Class 1 is appropriate for device. Improperly labeled - omitted labels required under 21 CFR 1040.10 / IEC 60825-1 via LN#56. Missing certification and proper manufacturer's ID label. Was not accompanied by compliant User Information. Formalized quality control procedures and record keeping of QC testing was not performed to IEC 60825-1 nor 21 CFR 1040.10 standards. Sales information did not convey required class designation and warning statement

Aug 5, 2026Terex Utilities
Medical DeviceUSFDA Devices

L-Cath Midline S/L Catheter 20ga (3F) 1mm x 20cm, REF: 384620

Argon Medical Devices, Inc
FDA DevicesClass II

L-Cath Midline S/L Catheter 20ga (3F) 1mm x 20cm, REF: 384620

Catheters, indicated for short/long-term peripheral access to central venous system for the administration of fluids, medications, nutrients; and sampling, may experience leaking and/or cracking at the hub, which may lead to replacement, inability to flush/aspirate catheter, catheter occlusion, therapy interruption, blood loss, tissue irritation, bloodstream infection.

Aug 5, 2026Argon Medical Devices, Inc
Medical DeviceUSFDA Devices

Brilliance iCT Brilliance iCT Upgrades Brilliance iCT SP Brilliance CT 64 Channel CT6000 Brilliance 64 Upgrades

PHILIPS MEDICAL SYSTEMS
FDA DevicesClass II

Brilliance iCT Brilliance iCT Upgrades Brilliance iCT SP Brilliance CT 64 Channel CT6000 Brilliance 64 Upgrades

The clinical CT scan may not automatically trigger after the Bolus Tracking scan and may need to be triggered manually. Additional Bolus Tracking shots may occur. This may result in the clinical acquisition being inadequate for diagnosis, causing a potential for patient rescan and receiving additional radiation.

Aug 5, 2026PHILIPS MEDICAL SYSTEMS
Medical DeviceUSFDA Devices

Stryker Hoffmann II Connecting Rod Micro 3 x 50mm. Catalog Number: 50796050.

Stryker GmbH
FDA DevicesClass II

Stryker Hoffmann II Connecting Rod Micro 3 x 50mm. Catalog Number: 50796050.

Potential cracking of the Hoffmann II Carbon Connecting Rods following cleaning and sterilization.

Aug 5, 2026Stryker GmbH
Medical DeviceUSFDA Devices

Pack Angiography NCMC 3/Cs BANNER, REF: NCAG62I, containing Medline Namic Angiographic Star Off Handle Manifolds

Medical Action Industries, Inc. 306
FDA DevicesClass I

Pack Angiography NCMC 3/Cs BANNER, REF: NCAG62I, containing Medline Namic Angiographic Star Off Handle Manifolds

Cardiovascular procedure kits contain manifolds, the subject of another recall, that may have particulate within the fluid path, which has the potential to be introduced into blood circulation and become lodged within blood vessels.

Aug 5, 2026Medical Action Industries, Inc. 306
Medical DeviceUSFDA Devices

AMS ALIGNED MEDICAL SOLUTIONS medical convenience kits labeled as: 1) Laminectomy Pack, Pack Number AMS13574A; 2) ACDF/Fusion Pack, Pack Number AMS14710B; 3) Spine Pack, Pack Number AMS14991A; 4) Spine Pack, Pack Number AMS14991B; 5) Spinal Pack, Pack Number AMS16278; 6) Spine Pack, Pack Number AMS16499; 7) Spine Pack, Pack Number AMS16709; 8) Lumbar Spine Pack, Pack Number AMS17336; 9) Laminectomy Pack, Pack Number AMS17945; 10) Anterior Cervical Pack, Pack Number AMS17946; 11) Spine Pack, Pack Number AMS3150F; 12) Spine Pack, Pack Number AMS3150G; 13) Spine Pack, Pack Number AMS5451D; 14) ENT Pack, Pack Number AMS9771.

Windstone Medical Packaging, Inc.
FDA DevicesClass II

AMS ALIGNED MEDICAL SOLUTIONS medical convenience kits labeled as: 1) Laminectomy Pack, Pack Number AMS13574A; 2) ACDF/Fusion Pack, Pack Number AMS14710B; 3) Spine Pack, Pack Number AMS14991A; 4) Spine Pack, Pack Number AMS14991B; 5) Spinal Pack, Pack Number AMS16278; 6) Spine Pack, Pack Number AMS16499; 7) Spine Pack, Pack Number AMS16709; 8) Lumbar Spine Pack, Pack Number AMS17336; 9) Laminectomy Pack, Pack Number AMS17945; 10) Anterior Cervical Pack, Pack Number AMS17946; 11) Spine Pack, Pack Number AMS3150F; 12) Spine Pack, Pack Number AMS3150G; 13) Spine Pack, Pack Number AMS5451D; 14) ENT Pack, Pack Number AMS9771.

The recall notice was initiated due to a Medicom Urgent Medical Device Recall. Medicom is recalling specific lots of Ritmed¿ Neurological Sponges Non-Sterile Models 55992C to 55998C due to potential for unexpected variability of endotoxin levels on the products.

Aug 5, 2026Windstone Medical Packaging, Inc.
Medical DeviceUSFDA Devices

AMS ALIGNED MEDICAL SOLUTIONS medical convenience kits labeled as: Angio Pack - RX, Part Number AMS9461

Windstone Medical Packaging, Inc.
FDA DevicesClass II

AMS ALIGNED MEDICAL SOLUTIONS medical convenience kits labeled as: Angio Pack - RX, Part Number AMS9461

Windstone Medical Packaging issued a recall for specific item(s) and lot(s) of Aligned Medical Solutions (AMS) convenience kits containing Elevaris Lidocaine HCl injection USP. Elevaris Medical Devices Inc. recalled the Lidocaine HCl injection USP due to supplier quality issues.

Aug 5, 2026Windstone Medical Packaging, Inc.
Medical DeviceUSFDA Devices

Stryker Hoffmann II Connecting Rod Micro 3 x 150mm. Catalog Number: 50796150.

Stryker GmbH
FDA DevicesClass II

Stryker Hoffmann II Connecting Rod Micro 3 x 150mm. Catalog Number: 50796150.

Potential cracking of the Hoffmann II Carbon Connecting Rods following cleaning and sterilization.

Aug 5, 2026Stryker GmbH
Medical DeviceUSFDA Devices

GEM Premier 5000 with IQM2 Model/Catalog Number: 00024019255 and GEM Premier 7000 with iQM3 Model/Catalog Number: 00000015279 Portable blood analyzer system. Affected Accessory: Bar Code Reader (BCR) Wand Part No. 00024015859

Instrumentation Laboratory
FDA DevicesClass II

GEM Premier 5000 with IQM2 Model/Catalog Number: 00024019255 and GEM Premier 7000 with iQM3 Model/Catalog Number: 00000015279 Portable blood analyzer system. Affected Accessory: Bar Code Reader (BCR) Wand Part No. 00024015859

Potential for Bar Code Reader (BCR) wands, used with the GEM Premier 5000 and GEM Premier 7000 systems, to assign patient results to an incorrect patient ID.

Aug 5, 2026Instrumentation Laboratory
Medical DeviceUSFDA Devices

EOPA Elongated One-Piece Arterial Cannula BLUNT 22FR, intended for use with cardiopulmonary bypass as an arterial return cannula, Model Number 77522

Medtronic Perfusion Systems
FDA DevicesClass II

EOPA Elongated One-Piece Arterial Cannula BLUNT 22FR, intended for use with cardiopulmonary bypass as an arterial return cannula, Model Number 77522

Pinhole leaks may occur in the wire-wound body during cardiopulmonary bypass. Potential risks associated with this condition may include hypovolemia, vessel laceration or perforation, hypotension, ischemia, and organ dysfunction.

Aug 5, 2026Medtronic Perfusion Systems