TRUE METRIX® Blood Glucose Monitoring Systems
TRUE METRIX® Blood Glucose Monitoring Systems
The former liquidator for Trividia Health Australia Pty Ltd (deregistered) is facilitating a product correction for TRUE METRIX® Blood Glucose Monitoring Systems....
Rifton TRAM and E-Pacer patient transfer and gait training devices
Rifton TRAM and E-Pacer patient transfer and gait training devices
Apex Mobility is conducting a product correction on the Rifton TRAM and E-Pacer patient transfer and gait training mobility devices....
Dynarex Obstetrical Towelettes Cleanser (Benzalkonium Chloride 0.13%), 100 packets, 5" x 7", Manufactured for Dynarex Corporation, 10 Glenshaw Street, Orangeburg, NY 10962, USA Made in USA, NDC 67777-244-02
Dynarex Obstetrical Towelettes Cleanser (Benzalkonium Chloride 0.13%), 100 packets, 5" x 7", Manufactured for Dynarex Corporation, 10 Glenshaw Street, Orangeburg, NY 10962, USA Made in USA, NDC 67777-244-02
CGMP Deviations
Metoprolol Succinate Extended-Release Tablets, Rx Only, 100 mg, 100 tablets bottles (NDC: 45963-677-11) and 1,000 tablets bottles (NDC: 45963-677-96), Teva Pharmaceuticals, Parsippany, NJ 07054.
Metoprolol Succinate Extended-Release Tablets, Rx Only, 100 mg, 100 tablets bottles (NDC: 45963-677-11) and 1,000 tablets bottles (NDC: 45963-677-96), Teva Pharmaceuticals, Parsippany, NJ 07054.
Failed Dissolution Specifications
Mack Trucks, Inc. - ECU Software Error May Cause Unexpected Vehicle Movement/FMVSS 102
Mack Trucks, Inc. - ECU Software Error May Cause Unexpected Vehicle Movement/FMVSS 102
Starting the vehicle while in gear may cause unexpected vehicle movement, increasing the risk of a crash or injury.
Children's Healthcare of Atlanta, Instant Hand Sanitizing Wipe(Benzalkonium Chloride 0.13%), 1000 per case, Made in USA for Food Service Resources, Flowery Branch, GA 30542, NDC 0924-7130-00
Children's Healthcare of Atlanta, Instant Hand Sanitizing Wipe(Benzalkonium Chloride 0.13%), 1000 per case, Made in USA for Food Service Resources, Flowery Branch, GA 30542, NDC 0924-7130-00
CGMP Deviations
Junebar Chocolate Cherry All Natural Snack Bar; INGREDIENTS: ORGANIC ALMOND BUTTER, DATE PASTE, ORGANIC BLACK BEANS, ORGANIC SWEET POTATOES, GLUTEN FREE ROLLED OATS, SEMI-SWEET SOY FREE VEGAN CHOCOLATE CHIPS (ORGANIC CANE SUGAR, UNSWEETENED CHOCOLATE, COCOA BUTTER), DRIED CHERRIES, ALMONDS; OAT FLOUR, COCOA POWDER, ORANGE ZEST, VANILLA EXTRACT (VANILLA BEAN EXTRACTIVES IN WATER, ALCOHOL), FLAX, CINNAMON, SEA SALT, BAKING POWDER; ALLERGEN WARNING: CONTAINS TREE NUTS (ALMOND, COCONUT), PRODUCED ON EQUPMENT ALSO HANDLING PEANUT, SESAME. PRODUCED IN A FACILITY THAT ALSO PROCESES GLUTEN PRODUCTS. KEEP REFRIGERATED; UPC: 8 60012 38462 4
Junebar Chocolate Cherry All Natural Snack Bar; INGREDIENTS: ORGANIC ALMOND BUTTER, DATE PASTE, ORGANIC BLACK BEANS, ORGANIC SWEET POTATOES, GLUTEN FREE ROLLED OATS, SEMI-SWEET SOY FREE VEGAN CHOCOLATE CHIPS (ORGANIC CANE SUGAR, UNSWEETENED CHOCOLATE, COCOA BUTTER), DRIED CHERRIES, ALMONDS; OAT FLOUR, COCOA POWDER, ORANGE ZEST, VANILLA EXTRACT (VANILLA BEAN EXTRACTIVES IN WATER, ALCOHOL), FLAX, CINNAMON, SEA SALT, BAKING POWDER; ALLERGEN WARNING: CONTAINS TREE NUTS (ALMOND, COCONUT), PRODUCED ON EQUPMENT ALSO HANDLING PEANUT, SESAME. PRODUCED IN A FACILITY THAT ALSO PROCESES GLUTEN PRODUCTS. KEEP REFRIGERATED; UPC: 8 60012 38462 4
Products contain undeclared milk and soy.
Premium Food Bubble Gum, packed in 2.5 oz clear flexible plastic packaging, all lots and codes. Sold in unit case of 30 LB.
Premium Food Bubble Gum, packed in 2.5 oz clear flexible plastic packaging, all lots and codes. Sold in unit case of 30 LB.
Contains undeclared colors (FD&C Blue 1 Lake and FD&C Blue 2 Lake).
Hand Sanitizing Wipes (Benzalkonium Chloride 0.13%), 1000 per case, Acme United Corporation, 2280 Tanner Road, Rocky Mount, NC 27801, NDC 0924-0301-00
Hand Sanitizing Wipes (Benzalkonium Chloride 0.13%), 1000 per case, Acme United Corporation, 2280 Tanner Road, Rocky Mount, NC 27801, NDC 0924-0301-00
CGMP Deviations
Lobster & Crab Ravioli. Keep Frozen. Contains: Wheat, Eggs, Milk, Crustaceans-Shellfish. Product is intended to be further cooked. Weight: 1-10 pound (4.5g). Use within 6 months. 801-541-9292-www.FunarosPerfectPasta.com. 1391 So. 300 West Slc, Ut 84115.
Lobster & Crab Ravioli. Keep Frozen. Contains: Wheat, Eggs, Milk, Crustaceans-Shellfish. Product is intended to be further cooked. Weight: 1-10 pound (4.5g). Use within 6 months. 801-541-9292-www.FunarosPerfectPasta.com. 1391 So. 300 West Slc, Ut 84115.
Undeclared shrimp, crab, lobster, pollock (fish), whiting (fish), and soy.
VERGANI 1944 MILANO 'PANDORO CLASSICO' Gluten Free, 600g NET WT. 1 LBS. 5.2 OZ., packaged in paper cartons, 6 units per case. Lot 217666, UPC 8002114019833
VERGANI 1944 MILANO 'PANDORO CLASSICO' Gluten Free, 600g NET WT. 1 LBS. 5.2 OZ., packaged in paper cartons, 6 units per case. Lot 217666, UPC 8002114019833
Potential contamination with foreign material (Teflon fragments) from flaking cooking molds.
CS100 IABP. Software Version CS100 IABP Q.01.
CS100 IABP. Software Version CS100 IABP Q.01.
The firm has identified that the battery runtime and cycle specifications contained in the devices Instructions for Use (IFU) need to be updated.
Esaote Endocavity ultrasonic probe, Model E 3-12, REF 120000038
Esaote Endocavity ultrasonic probe, Model E 3-12, REF 120000038
A potential weakness has been identified in the probe body, so that, in a specific production batch, liquid may leak from the terminal part of the casing near the cable.
GE Healthcare Centricity Universal Viewer Zero Footprint Client, Model Numbers: 2110344-039, 2110344-046, 2110344-047; System, Image Processing, Radiological
GE Healthcare Centricity Universal Viewer Zero Footprint Client, Model Numbers: 2110344-039, 2110344-046, 2110344-047; System, Image Processing, Radiological
Under certain workflows, patient information shown in the viewer may not match the images displayed on Centricity Universal Viewer Zero Footprint Client (ZFP) with versions ZFP v6.0: SP11.6, SP11.6.0.1 and SP11.6.1 on systems with Patient Timeline installed,
BZK Antiseptic Towelettes (Benzalkonium Chloride 0.13%), 5" x7", 1000 ea Bulk, Med-Nap, Brooksville, FL 34601, Made in USA, NDC 0924-0246-02.
BZK Antiseptic Towelettes (Benzalkonium Chloride 0.13%), 5" x7", 1000 ea Bulk, Med-Nap, Brooksville, FL 34601, Made in USA, NDC 0924-0246-02.
CGMP Deviations
Med-Nap Cleansing Towelettes (Benzalkonium Chloride 0.13%), 100 Towelettes, Manufactured by: Acme United Corporation, 1 Waterview Dr., Stelton, CT 06484, NDC 0924-0243-01.
Med-Nap Cleansing Towelettes (Benzalkonium Chloride 0.13%), 100 Towelettes, Manufactured by: Acme United Corporation, 1 Waterview Dr., Stelton, CT 06484, NDC 0924-0243-01.
CGMP Deviations
Medi-First Antiseptic Wipes (BZK)(Benzalkonium Chloride 0.13%), 100 wipes per box, Manufactured for Medique Products, Fort Meyers, FL, 33967, NDC 47682-122-33.
Medi-First Antiseptic Wipes (BZK)(Benzalkonium Chloride 0.13%), 100 wipes per box, Manufactured for Medique Products, Fort Meyers, FL, 33967, NDC 47682-122-33.
CGMP Deviations
tippy toes apple pear banana 6 months & up baby food 2-4OZ (113g) PACKS NET WT 8 OZ (226g) DISTRIBUTED BY TOPCO ASSOCIATES LLC ELK GROVE VILLAGE, IL 60007 1-888-423-0139 PRODUCT OF USA UPC: 036800265783
tippy toes apple pear banana 6 months & up baby food 2-4OZ (113g) PACKS NET WT 8 OZ (226g) DISTRIBUTED BY TOPCO ASSOCIATES LLC ELK GROVE VILLAGE, IL 60007 1-888-423-0139 PRODUCT OF USA UPC: 036800265783
Potential contamination with patulin.
Amnesteem (Isotretinoin) Capsules, USP 40 mg, packaged in 3 x 10-Count Prescription Packs, Rx Only, Manufactured for: Mylan Pharmaceuticals Inc., Morgantown, WV, 26505 USA, Made in France, NDC 0378-6614-93.
Amnesteem (Isotretinoin) Capsules, USP 40 mg, packaged in 3 x 10-Count Prescription Packs, Rx Only, Manufactured for: Mylan Pharmaceuticals Inc., Morgantown, WV, 26505 USA, Made in France, NDC 0378-6614-93.
Failed Dissolution Specifications
Brand Name: Olympus ShockPulse-SE Lithotripsy System with Generator Product Name: ShockPulse-SE Lithotripsy System - Reuseable Probes Model/Catalog Number: SPL-SR, contains generator SPL-G Product Description: An assembly of devices that uses a combination of, or individually applied, pneumatically-created ballistic shock waves and ultrasonic waves for the intracorporeal fragmentation of stones (calculi) in the urinary tract (i.e., kidney, ureter, and bladder) for their removal. It typically includes a pressure and power regulator/control unit, handpieces, and two types of probes of various sizes. The probes are attached to the two handpieces which are connected to the control unit that supplies the energy for both the pneumatic and ultrasonic functions. Energy is applied to a calculus which is fragmented in situ and removed via a suction system facilitated by the lithotripsy system.
Brand Name: Olympus ShockPulse-SE Lithotripsy System with Generator Product Name: ShockPulse-SE Lithotripsy System - Reuseable Probes Model/Catalog Number: SPL-SR, contains generator SPL-G Product Description: An assembly of devices that uses a combination of, or individually applied, pneumatically-created ballistic shock waves and ultrasonic waves for the intracorporeal fragmentation of stones (calculi) in the urinary tract (i.e., kidney, ureter, and bladder) for their removal. It typically includes a pressure and power regulator/control unit, handpieces, and two types of probes of various sizes. The probes are attached to the two handpieces which are connected to the control unit that supplies the energy for both the pneumatic and ultrasonic functions. Energy is applied to a calculus which is fragmented in situ and removed via a suction system facilitated by the lithotripsy system.
Mis-wired component-the improperly wired component can result in additional noise on the power supply output. Noise on the ultrasonic input circuit is not consistent with electromagnetic compatibility (EMC) standards and may decrease the overall reliability of the system and result in delay of treatment. It was discovered that additional serial numbers of ShockPulse generators may also have the mis-wired component. As a result, this is expanding the action to the additional impacted devices.
Brand Name: ShockPulse-SE Lithotripsy System SPL-SR Product Name: ShockPulse-SE Lithotripsy System - Reusable Probes Model/Catalog Number: SPL-SR Product Description: The ShockPulse Lithotripsy System is an electromechanical device capable of fragmenting calculi and aspirating stone debris. The ShockPulse transducer is a reusable device that requires cleaning and steam sterilization prior to use in order to generate both low-frequency mechanical impacts and high-frequency ultrasonic energy that quickly disintegrates stones.
Brand Name: ShockPulse-SE Lithotripsy System SPL-SR Product Name: ShockPulse-SE Lithotripsy System - Reusable Probes Model/Catalog Number: SPL-SR Product Description: The ShockPulse Lithotripsy System is an electromechanical device capable of fragmenting calculi and aspirating stone debris. The ShockPulse transducer is a reusable device that requires cleaning and steam sterilization prior to use in order to generate both low-frequency mechanical impacts and high-frequency ultrasonic energy that quickly disintegrates stones.
Ongoing investigations identified additional instances of the device Generator remaining in a blinking phase waiting to recognize the transducer. Damage to the transducer plug and/or generator receptacle may cause these issues.
Brand Name: STA Liatest Free Protein S Product Name: STA Liatest Free Protein S Model/Catalog Number (REF): 00516 Product Description: The STA¿ - Liatest¿ Free Protein S kits are intended for use on STA-R¿ and STA Compact¿ for the quantitative antigenic assay of free protein S in human citrated plasma by the immuno-turbidimetric method. Component: Not Applicable
Brand Name: STA Liatest Free Protein S Product Name: STA Liatest Free Protein S Model/Catalog Number (REF): 00516 Product Description: The STA¿ - Liatest¿ Free Protein S kits are intended for use on STA-R¿ and STA Compact¿ for the quantitative antigenic assay of free protein S in human citrated plasma by the immuno-turbidimetric method. Component: Not Applicable
The potential of out-of-range results and an underestimation of the free protein S level in normal patient plasmas. The defect only affects normal-range values.
Med Nap BZK Antiseptic Towelettes (Benzalkonium Chloride 0.13%), 100 Towelettes, Manufactured by: Acme United Corporation, 1 Waterview Dr, Shelton, CT 06481, NDC 0924-0246-01.
Med Nap BZK Antiseptic Towelettes (Benzalkonium Chloride 0.13%), 100 Towelettes, Manufactured by: Acme United Corporation, 1 Waterview Dr, Shelton, CT 06481, NDC 0924-0246-01.
CGMP Deviations
cobas pro integrated solutions with cobas c 503 analytical units: cobas pro sample supply unit, material number 08464502001 cobas pro SSU, material number 09205632001 Affected Assays: (Product Name/ Catalog Number/ Application Code/ Application Short Name) 1. Cystatin C Gen.2 08105596190 20510 CYSC2 2. Ferritin Gen.4 08057648190 20571 FER4X 3. Lipoprotein (a) Gen.2 08106126190 20861 LPA2X 4. Lipoprotein (a) molarity 08106126160 20864 LPA2-X 5. Vancomycin Gen.3 08058849190 21211 VANC3O 6. Kappa Free Light Chains Partner Channel 08896640190 21421 KFLCX 7. Lambda Free Light Chains Partner Channel 08896631190 21430 LFLC 8. fCAL turbo Partner Channel 08910367190 21490 FCAL
cobas pro integrated solutions with cobas c 503 analytical units: cobas pro sample supply unit, material number 08464502001 cobas pro SSU, material number 09205632001 Affected Assays: (Product Name/ Catalog Number/ Application Code/ Application Short Name) 1. Cystatin C Gen.2 08105596190 20510 CYSC2 2. Ferritin Gen.4 08057648190 20571 FER4X 3. Lipoprotein (a) Gen.2 08106126190 20861 LPA2X 4. Lipoprotein (a) molarity 08106126160 20864 LPA2-X 5. Vancomycin Gen.3 08058849190 21211 VANC3O 6. Kappa Free Light Chains Partner Channel 08896640190 21421 KFLCX 7. Lambda Free Light Chains Partner Channel 08896631190 21430 LFLC 8. fCAL turbo Partner Channel 08910367190 21490 FCAL
Software defect, which allows the system to accept erroneous, non-monotonous calibrations for Spline-type assays. Cobas pro integrated solutions is an automated analyzer, intended for running qualitative, semi-quantitative and quantitative clinical chemistry and immunochemistry assays, as well as ion-selective measurements. When an erroneous calibration is active, the instrument fails to calculate new values and instead repeats the last successfully calculated result from any Spline-type assay for all subsequent measurements, leading to identical and erroneous patient and QC results. The defect could lead to patients receiving erroneous lab results, which could result in a remote risk of serious adverse health consequences. The following assays use spline type calibration and are affected by this issue: Cystatin C Gen.2, Ferritin Gen.4, Lipoprotein (a) Gen. 2, Lipoprotein (a) molarity, Vancomycin Gen.3, Kappa Free Light Chains Partner Channel, Lambda Free Light Chains Partner Channel, and fCAL turbo Partner Channel.