eTRAX Needle System Starter Kit 18G (for Aurora Trackers), Part Number 667-152

Civco Medical Instruments Co. Inc.
FDA DevicesClass II

eTRAX Needle System Starter Kit 18G (for Aurora Trackers), Part Number 667-152

There was an error in inspection and programming of the eTRAX needle sensor for Aurora trackers. The result is a potential for the needle tip position to be incorrectly identified on the user interface.

Apr 8, 2026Civco Medical Instruments Co. Inc.
Medical DeviceUSFDA Devices

Brand Name: da Vinci S, Si Grasping Retractor Instrument Product Name: da Vinci S, Si Grasping Retractor Instrument Model/Catalog Number: 420278 Software Version: NA Product Description: EndoWrist Instruments or Da Vinci S/Si Reusable instruments, including blunt and sharp endoscopic dissectors, scissors, scalpels, forceps/pick-ups, needle holders, endoscopic retractors, electrocautery and accessories are intended for endoscopic manipulation of tissue, including grasping, cutting, blunt and sharp dissection, approximation, ligation, electrocautery, suturing, and delivery and placement of microwave and cryogenic ablation probes and accessories. Please refer to attached User Manual for additional details on intended use. All da Vinci S/Si reusable instruments with jaws use mechanical tungsten cables and pulleys to transmit motion from the input discs to the housing (on the proximal chassis), through the main shaft, and the distal instrument tip (inside the patient). Component: NA

Intuitive Surgical, Inc.
FDA DevicesClass II

Brand Name: da Vinci S, Si Grasping Retractor Instrument Product Name: da Vinci S, Si Grasping Retractor Instrument Model/Catalog Number: 420278 Software Version: NA Product Description: EndoWrist Instruments or Da Vinci S/Si Reusable instruments, including blunt and sharp endoscopic dissectors, scissors, scalpels, forceps/pick-ups, needle holders, endoscopic retractors, electrocautery and accessories are intended for endoscopic manipulation of tissue, including grasping, cutting, blunt and sharp dissection, approximation, ligation, electrocautery, suturing, and delivery and placement of microwave and cryogenic ablation probes and accessories. Please refer to attached User Manual for additional details on intended use. All da Vinci S/Si reusable instruments with jaws use mechanical tungsten cables and pulleys to transmit motion from the input discs to the housing (on the proximal chassis), through the main shaft, and the distal instrument tip (inside the patient). Component: NA

Due to increased complaints for broken/frayed grip cables for reusable instruments.

Apr 8, 2026Intuitive Surgical, Inc.
Medical DeviceUSFDA Devices

Azurion 5 M12; System Code: (1)722227, (2)722231;

PHILIPS MEDICAL SYSTEMS NEDERLAND B.V.
FDA DevicesClass II

Azurion 5 M12; System Code: (1)722227, (2)722231;

Philips has identified instances where X-ray imaging may not be initiated or may occur intermittently when using the wired foot switch.

Apr 8, 2026PHILIPS MEDICAL SYSTEMS NEDERLAND B.V.
Medical DeviceUSFDA Devices

Burlington Medical, Wrap Aprons.

Burlington Medical, LLC
FDA DevicesClass II

Burlington Medical, Wrap Aprons.

Potential for attenuation degradation over time, decreasing the lifespan.

Apr 8, 2026Burlington Medical, LLC
Medical DeviceUSFDA Devices

Paradigm REAL-Time Insulin Pump (MMT-522, MMT-722)

Medtronic MiniMed, Inc.
FDA DevicesClass II

Paradigm REAL-Time Insulin Pump (MMT-522, MMT-722)

All Medtronic MiniMed infusion pumps (Paradigm series, 600 series, and BLE 700 series) were found to be affected by unintended over- and under-delivery of insulin when the pump is elevated or lowered relative to the infusion site, respectively, because of changes in gravitational force impacting hydrostatic and hydrodynamic pressures. Insulin over-delivery, which can occur when the pump is elevated relative to the infusion site, can result in severe hypoglycemia, altered mental status, seizure, coma, or death. An under-delivery of insulin, which can occur at lowered pump height conditions relative to the infusion site, can result in severe hyperglycemia, dehydration, diabetic ketoacidosis, or death.

Apr 8, 2026Medtronic MiniMed, Inc.
Medical DeviceUSFDA Devices

Medline convenience kits containing Olympus biopsy valves: 1. BRONCH PACK, DYKE2096 2. NON MB BRONCHOPSCOPY CCH LH PK, DYNJT6182 3. PULMONARY BRONCH PACK, DYNDA2861A

Medline Industries, LP
FDA DevicesClass II

Medline convenience kits containing Olympus biopsy valves: 1. BRONCH PACK, DYKE2096 2. NON MB BRONCHOPSCOPY CCH LH PK, DYNJT6182 3. PULMONARY BRONCH PACK, DYNDA2861A

Kits contain recalled Olympus biopsy valves. Olympus is investigating an increase in complaints associated with rubber fragment detachment in the slit of single use biopsy valves. Potential consequences associated with detachment of fragments from valve include foreign body in patient's tracheobronchial tree, which may require intervention for removal. Other potential consequences include inflammatory response, hypoxia, and prolongation of procedure.

Apr 8, 2026Medline Industries, LP
Medical DeviceUSFDA Devices

eTRAX Needle System Starter Kit 14G (for Aurora Trackers), Part Number 667-150

Civco Medical Instruments Co. Inc.
FDA DevicesClass II

eTRAX Needle System Starter Kit 14G (for Aurora Trackers), Part Number 667-150

There was an error in inspection and programming of the eTRAX needle sensor for Aurora trackers. The result is a potential for the needle tip position to be incorrectly identified on the user interface.

Apr 8, 2026Civco Medical Instruments Co. Inc.
Medical DeviceUSFDA Devices

MiniMed 700G Insulin Pump (MMT-1801, MMT-1805, MMT-1850, MMT-1851)

Medtronic MiniMed, Inc.
FDA DevicesClass II

MiniMed 700G Insulin Pump (MMT-1801, MMT-1805, MMT-1850, MMT-1851)

All Medtronic MiniMed infusion pumps (Paradigm series, 600 series, and BLE 700 series) were found to be affected by unintended over- and under-delivery of insulin when the pump is elevated or lowered relative to the infusion site, respectively, because of changes in gravitational force impacting hydrostatic and hydrodynamic pressures. Insulin over-delivery, which can occur when the pump is elevated relative to the infusion site, can result in severe hypoglycemia, altered mental status, seizure, coma, or death. An under-delivery of insulin, which can occur at lowered pump height conditions relative to the infusion site, can result in severe hyperglycemia, dehydration, diabetic ketoacidosis, or death.

Apr 8, 2026Medtronic MiniMed, Inc.
Medical DeviceUSFDA Devices

ALLURA Xper FD20; System Code: (1) 722006, (2)722012, (3)722028;

PHILIPS MEDICAL SYSTEMS NEDERLAND B.V.
FDA DevicesClass II

ALLURA Xper FD20; System Code: (1) 722006, (2)722012, (3)722028;

Philips has identified instances where X-ray imaging may not be initiated or may occur intermittently when using the wired foot switch.

Apr 8, 2026PHILIPS MEDICAL SYSTEMS NEDERLAND B.V.
Medical DeviceUSFDA Devices

CPX 4 US Breast Tissue Expanders with Suture Tabs Reference Numbers: SCPX-113TH, SCPX-123TH, SCPX-140TH, SCPX-146TH Smooth Tall Height Tissue Expander, 350cc, 450cc, 650cc, 750cc

Mentor Texas, LP.
FDA DevicesClass II

CPX 4 US Breast Tissue Expanders with Suture Tabs Reference Numbers: SCPX-113TH, SCPX-123TH, SCPX-140TH, SCPX-146TH Smooth Tall Height Tissue Expander, 350cc, 450cc, 650cc, 750cc

Infusion sets may contain dull/blunt needle tip, which may be difficult to advance, and/or break.

Apr 8, 2026Mentor Texas, LP.
Medical DeviceUSFDA Devices

Burlington Medical, Demi Half Aprons.

Burlington Medical, LLC
FDA DevicesClass II

Burlington Medical, Demi Half Aprons.

Potential for attenuation degradation over time, decreasing the lifespan.

Apr 8, 2026Burlington Medical, LLC
Medical DeviceUSFDA Devices

Artoura Breast Tissue Expanders Reference Numbers: TEXP110RH TEXP120RH TEXP120RUH TEXP130RH TEXP135RH TEXP140RH TEXP150RH Textured, High & Ultra High Profile, Integral Injection Dome, 300cc, 375cc, 535cc, 475cc, 500cc, 600cc, 750cc,

Mentor Texas, LP.
FDA DevicesClass II

Artoura Breast Tissue Expanders Reference Numbers: TEXP110RH TEXP120RH TEXP120RUH TEXP130RH TEXP135RH TEXP140RH TEXP150RH Textured, High & Ultra High Profile, Integral Injection Dome, 300cc, 375cc, 535cc, 475cc, 500cc, 600cc, 750cc,

Infusion sets may contain dull/blunt needle tip, which may be difficult to advance, and/or break.

Apr 8, 2026Mentor Texas, LP.
Medical DeviceUSFDA Devices

Allura Xper FD20/20; System Code: 722038;

PHILIPS MEDICAL SYSTEMS NEDERLAND B.V.
FDA DevicesClass II

Allura Xper FD20/20; System Code: 722038;

Philips has identified instances where X-ray imaging may not be initiated or may occur intermittently when using the wired foot switch.

Apr 8, 2026PHILIPS MEDICAL SYSTEMS NEDERLAND B.V.
Medical DeviceUSFDA Devices

Allura Xper FD20/15; System Code: 722058;

PHILIPS MEDICAL SYSTEMS NEDERLAND B.V.
FDA DevicesClass II

Allura Xper FD20/15; System Code: 722058;

Philips has identified instances where X-ray imaging may not be initiated or may occur intermittently when using the wired foot switch.

Apr 8, 2026PHILIPS MEDICAL SYSTEMS NEDERLAND B.V.
Medical DeviceUSFDA Devices

Burlington Medical, Blockers.

Burlington Medical, LLC
FDA DevicesClass II

Burlington Medical, Blockers.

Potential for attenuation degradation over time, decreasing the lifespan.

Apr 8, 2026Burlington Medical, LLC
Medical DeviceUSFDA Devices

BD Kiestra" ReadA; Catalog No.: 446948.

BD KIESTRA LAB AUTOMATION
FDA DevicesClass II

BD Kiestra" ReadA; Catalog No.: 446948.

In certain situations, following a system reboot, one or more modules may have become unreachable via the remote connectivity interface. When this occurred, there was potential for delays in plate retrieval from the incubator while connectivity was restored. This issue was intermittent and did not affect test results, performance of the assay, or sample integrity.

Apr 8, 2026BD KIESTRA LAB AUTOMATION
Medical DeviceUSFDA Devices

ALLURA Xper FD10; System Code: (1) 722003, (2)722010, (3)722026;

PHILIPS MEDICAL SYSTEMS NEDERLAND B.V.
FDA DevicesClass II

ALLURA Xper FD10; System Code: (1) 722003, (2)722010, (3)722026;

Philips has identified instances where X-ray imaging may not be initiated or may occur intermittently when using the wired foot switch.

Apr 8, 2026PHILIPS MEDICAL SYSTEMS NEDERLAND B.V.
Medical DeviceUSFDA Devices

Artoura Breast Tissue Expanders Reference Numbers: SDC-100H SDC-110H SDC-120H SDC-130H SDC-135H SDC-140H SDC-150H SDC-155H Smooth High Profile Tissue Expander, 225cc, 300cc, 375cc, 475cc, 500cc, 600cc, 750cc, 850cc

Mentor Texas, LP.
FDA DevicesClass II

Artoura Breast Tissue Expanders Reference Numbers: SDC-100H SDC-110H SDC-120H SDC-130H SDC-135H SDC-140H SDC-150H SDC-155H Smooth High Profile Tissue Expander, 225cc, 300cc, 375cc, 475cc, 500cc, 600cc, 750cc, 850cc

Infusion sets may contain dull/blunt needle tip, which may be difficult to advance, and/or break.

Apr 8, 2026Mentor Texas, LP.
Medical DeviceUSFDA Devices

Brand Name: Olympus SOLTIVE Premium SuperPulsed Laser System Product Name: SOLTIVE Premium Laser System TFL-PLS Model/Catalog Number: TFL-PLS containing TFL-CPLU Product Description: An electricity powered device assembly which emits a high-power laser beam to vaporize/ablate soft tissue with moderate hemostasis, little charring, and a thin zone of necrosis. Component: No

Olympus Corporation of the Americas
FDA DevicesClass II

Brand Name: Olympus SOLTIVE Premium SuperPulsed Laser System Product Name: SOLTIVE Premium Laser System TFL-PLS Model/Catalog Number: TFL-PLS containing TFL-CPLU Product Description: An electricity powered device assembly which emits a high-power laser beam to vaporize/ablate soft tissue with moderate hemostasis, little charring, and a thin zone of necrosis. Component: No

Following a complaint investigation, Olympus identified a potential defect in the 24V power supply module in some SOLTIVE laser units which may cause the system to become inoperable. Additionally, smoke or a burning smell may occur. By design, the issue causing the smoke or burning smell would be contained within the internal laser console enclosure and would be self-extinguishing.

Apr 8, 2026Olympus Corporation of the Americas
Medical DeviceUSFDA Devices

ALLURA Xper FD10F; System Code: 722002;

PHILIPS MEDICAL SYSTEMS NEDERLAND B.V.
FDA DevicesClass II

ALLURA Xper FD10F; System Code: 722002;

Philips has identified instances where X-ray imaging may not be initiated or may occur intermittently when using the wired foot switch.

Apr 8, 2026PHILIPS MEDICAL SYSTEMS NEDERLAND B.V.
Medical DeviceUSFDA Devices

Medline kits containing Olympus biopsy valves: 1. BRONCH PROCEDURE KIT, DYKE2091 2. BRONCHSCOPY, DYNJ900898G DYNJ901922I 3. BRONCHSCOPY PACK, DYNJ38313B 4. BRONCHOSCOPY PACK 0120367-LF, DYNJ32750G DYNJ32750I 5. KIT, WR THORACIC, DYNJ911252 6. LARYNGOSCOPY/BRONCHOSCOPY PACK, DYNJ58146B 7. LEX THORACIC, DYNJ902016K DYNJ902016L 8. ORGAN PROCUREMENT, DYNJ908686 9. PULMONARY PACK, DYKE1859 10. THORACIC, DYNJ901666L 11. THORACIC ROBOTICS, DYNJ908777A 12. THORACOTOMY/THORACOSCOPY, DYNJ900482N DYNJ900482O 13. XPS, DYNJ907605

Medline Industries, LP
FDA DevicesClass II

Medline kits containing Olympus biopsy valves: 1. BRONCH PROCEDURE KIT, DYKE2091 2. BRONCHSCOPY, DYNJ900898G DYNJ901922I 3. BRONCHSCOPY PACK, DYNJ38313B 4. BRONCHOSCOPY PACK 0120367-LF, DYNJ32750G DYNJ32750I 5. KIT, WR THORACIC, DYNJ911252 6. LARYNGOSCOPY/BRONCHOSCOPY PACK, DYNJ58146B 7. LEX THORACIC, DYNJ902016K DYNJ902016L 8. ORGAN PROCUREMENT, DYNJ908686 9. PULMONARY PACK, DYKE1859 10. THORACIC, DYNJ901666L 11. THORACIC ROBOTICS, DYNJ908777A 12. THORACOTOMY/THORACOSCOPY, DYNJ900482N DYNJ900482O 13. XPS, DYNJ907605

Kits contain recalled Olympus biopsy valves. Olympus is investigating an increase in complaints associated with rubber fragment detachment in the slit of single use biopsy valves. Potential consequences associated with detachment of fragments from valve include foreign body in patient's tracheobronchial tree, which may require intervention for removal. Other potential consequences include inflammatory response, hypoxia, and prolongation of procedure.

Apr 8, 2026Medline Industries, LP
Medical DeviceUSFDA Devices

MiniMed 770G Insulin Pump (MMT-1880, MMT-1881, MMT-1882, MMT-1890, MMT-1891, MMT-1892)

Medtronic MiniMed, Inc.
FDA DevicesClass II

MiniMed 770G Insulin Pump (MMT-1880, MMT-1881, MMT-1882, MMT-1890, MMT-1891, MMT-1892)

All Medtronic MiniMed infusion pumps (Paradigm series, 600 series, and BLE 700 series) were found to be affected by unintended over- and under-delivery of insulin when the pump is elevated or lowered relative to the infusion site, respectively, because of changes in gravitational force impacting hydrostatic and hydrodynamic pressures. Insulin over-delivery, which can occur when the pump is elevated relative to the infusion site, can result in severe hypoglycemia, altered mental status, seizure, coma, or death. An under-delivery of insulin, which can occur at lowered pump height conditions relative to the infusion site, can result in severe hyperglycemia, dehydration, diabetic ketoacidosis, or death.

Apr 8, 2026Medtronic MiniMed, Inc.
Medical DeviceUSFDA Devices

Brand Name: da Vinci S, Si Mega Needle Driver Instrument Product Name: da Vinci S, Si Mega Needle Driver Instrument Model/Catalog Number: 420194 Software Version: NA Product Description: EndoWrist Instruments or Da Vinci S/Si Reusable instruments, including blunt and sharp endoscopic dissectors, scissors, scalpels, forceps/pick-ups, needle holders, endoscopic retractors, electrocautery and accessories are intended for endoscopic manipulation of tissue, including grasping, cutting, blunt and sharp dissection, approximation, ligation, electrocautery, suturing, and delivery and placement of microwave and cryogenic ablation probes and accessories. Please refer to attached User Manual for additional details on intended use. All da Vinci S/Si reusable instruments with jaws use mechanical tungsten cables and pulleys to transmit motion from the input discs to the housing (on the proximal chassis), through the main shaft, and the distal instrument tip (inside the patient). Component: NA

Intuitive Surgical, Inc.
FDA DevicesClass II

Brand Name: da Vinci S, Si Mega Needle Driver Instrument Product Name: da Vinci S, Si Mega Needle Driver Instrument Model/Catalog Number: 420194 Software Version: NA Product Description: EndoWrist Instruments or Da Vinci S/Si Reusable instruments, including blunt and sharp endoscopic dissectors, scissors, scalpels, forceps/pick-ups, needle holders, endoscopic retractors, electrocautery and accessories are intended for endoscopic manipulation of tissue, including grasping, cutting, blunt and sharp dissection, approximation, ligation, electrocautery, suturing, and delivery and placement of microwave and cryogenic ablation probes and accessories. Please refer to attached User Manual for additional details on intended use. All da Vinci S/Si reusable instruments with jaws use mechanical tungsten cables and pulleys to transmit motion from the input discs to the housing (on the proximal chassis), through the main shaft, and the distal instrument tip (inside the patient). Component: NA

Due to increased complaints for broken/frayed grip cables for reusable instruments.

Apr 8, 2026Intuitive Surgical, Inc.
Medical DeviceUSFDA Devices

ALLURA Xper FD10/10; System Code: (1) 722005, (2)722011, (3)722027;

PHILIPS MEDICAL SYSTEMS NEDERLAND B.V.
FDA DevicesClass II

ALLURA Xper FD10/10; System Code: (1) 722005, (2)722011, (3)722027;

Philips has identified instances where X-ray imaging may not be initiated or may occur intermittently when using the wired foot switch.

Apr 8, 2026PHILIPS MEDICAL SYSTEMS NEDERLAND B.V.