Neuroguard IEP 3 in 1 Carotid Stent and Post-Dilation Balloon System with Integrated Embolic Protection (Neuroguard IEP System), REF: NG-0630-140-2, NG-0640-140-2, NG-0730-140-2, NG-0740-140-2, NG-NV-6-30, NG-NV-6-40, NG-NV-7-30, NG-NV-7-40
Neuroguard IEP 3 in 1 Carotid Stent and Post-Dilation Balloon System with Integrated Embolic Protection (Neuroguard IEP System), REF: NG-0630-140-2, NG-0640-140-2, NG-0730-140-2, NG-0740-140-2, NG-NV-6-30, NG-NV-6-40, NG-NV-7-30, NG-NV-7-40
Carotid stent and post-dilation balloon system with integrated embolic protection system has an integrated filter, that due to a wire-to-filter-bond issue, may fail to open following sheath retraction; and if this condition were to occur during a procedure, the result may be loss of intended integrated embolic protection.
Philips Azurion under the following System Descriptions and corresponding model numbers: 1. Azurion 3 M12; Model Numbers: 722063, 722221. 2. Azurion 3 M15; Model Numbers: 722064, 722222, 722280. 3. Azurion 5 M12; Model Number: 722227. 4. Azurion 5 M20; Model Numbers: 722228, 722281. 5. Azurion 7 B12; Model Numbers: 722067, 722225. 6. Azurion 7 B20; Model Numbers: 722068, 722226. 7. Azurion 7 M12; Model Numbers: 722078, 722223. 8. Azurion 7 M20; Model Numbers: 722079, 722224, 722282. Interventional Fluoroscopic X-Ray System.
Philips Azurion under the following System Descriptions and corresponding model numbers: 1. Azurion 3 M12; Model Numbers: 722063, 722221. 2. Azurion 3 M15; Model Numbers: 722064, 722222, 722280. 3. Azurion 5 M12; Model Number: 722227. 4. Azurion 5 M20; Model Numbers: 722228, 722281. 5. Azurion 7 B12; Model Numbers: 722067, 722225. 6. Azurion 7 B20; Model Numbers: 722068, 722226. 7. Azurion 7 M12; Model Numbers: 722078, 722223. 8. Azurion 7 M20; Model Numbers: 722079, 722224, 722282. Interventional Fluoroscopic X-Ray System.
Potential Loss of imaging functionality, loss of motorized movement, or loss of data due to unauthorized Hard Disk Drives.
REF # D23352, MicroScan LabPro V5.03 Panel Update 11 (US), Electronic installed on the following instruments: - B1018-280 MicroScan autoSCAN-4 Instrument - B1018-283 MicroScan WalkAway-40 plus Instrument - B1018-284 MicroScan WalkAway-96 plus Instrument - B1018-440 DxM-1040 MicroScan WalkAway Instrument - B1018-496 DxM-1096 MicroScan WalkAway Instrument
REF # D23352, MicroScan LabPro V5.03 Panel Update 11 (US), Electronic installed on the following instruments: - B1018-280 MicroScan autoSCAN-4 Instrument - B1018-283 MicroScan WalkAway-40 plus Instrument - B1018-284 MicroScan WalkAway-96 plus Instrument - B1018-440 DxM-1040 MicroScan WalkAway Instrument - B1018-496 DxM-1096 MicroScan WalkAway Instrument
Analyzers contain incorrect algorithms which may affect antimicrobial susceptibility test results, leading to false susceptibility classifications."
Brand Name: Quantum rehab Product Name: Q6 Edge 2.0 Model/Catalog Number: Q6 Edge 2.0 Software Version: 2.0.11, new version: 2.0.13 Product Description: Wheelchair, Powered (ITI), 890.3860 Component: Controller
Brand Name: Quantum rehab Product Name: Q6 Edge 2.0 Model/Catalog Number: Q6 Edge 2.0 Software Version: 2.0.11, new version: 2.0.13 Product Description: Wheelchair, Powered (ITI), 890.3860 Component: Controller
If the "Remind Me Later" option is selected for user reminders, reminder pop-up messages may appear while the wheelchair is in use. If this occurs while driving the wheelchair, the wheelchair may perform an unexpected park brake stop, which may result in fall or injury. If this occurs while not driving the wheelchair, the control system may crash and remain in pre-operational mode.
Field Safety Notices: 3 to 7 August 2026
Field Safety Notices: 3 to 7 August 2026
List of Field Safety Notices from 3 to 7 August 2026....
Devices supplied without valid UKCA/CE conformity markings or certification: remove from use and place in quarantine (DSI/2026/007)
Devices supplied without valid UKCA/CE conformity markings or certification: remove from use and place in quarantine (DSI/2026/007)
The MHRA has become aware of a number of medical devices being supplied on the UK market that do not comply with the requirements of the UK Medical Device Regulations 2002 (UK MDR 2002) or with the EU...
Belzer UW® Cold Storage Solution and Belzer MPS® (UW Machine Perfusion Solution): manufactured by Carnamedica (UKRP: Bridge to Life): Updated advice on the contamination of fluid DSI/2026/006 (update to DSI/2023/005)
Belzer UW® Cold Storage Solution and Belzer MPS® (UW Machine Perfusion Solution): manufactured by Carnamedica (UKRP: Bridge to Life): Updated advice on the contamination of fluid DSI/2026/006 (update to DSI/2023/005)
The MHRA is providing an update on defects previously identified with Belzer solutions for the preservation of donated organs. This DSI replaces advice in DSI/2023/005....
EOPA 3D Arterial Cannula 22FR, intended for use with cardiopulmonary bypass as an arterial return cannula, Model Number 78322
EOPA 3D Arterial Cannula 22FR, intended for use with cardiopulmonary bypass as an arterial return cannula, Model Number 78322
Pinhole leaks may occur in the wire-wound body during cardiopulmonary bypass. Potential risks associated with this condition may include hypovolemia, vessel laceration or perforation, hypotension, ischemia, and organ dysfunction.
L-Cath Midline S/L Catheter 20ga (3F) 1mm x 20cm, REF: 384620
L-Cath Midline S/L Catheter 20ga (3F) 1mm x 20cm, REF: 384620
Catheters, indicated for short/long-term peripheral access to central venous system for the administration of fluids, medications, nutrients; and sampling, may experience leaking and/or cracking at the hub, which may lead to replacement, inability to flush/aspirate catheter, catheter occlusion, therapy interruption, blood loss, tissue irritation, bloodstream infection.
AMS ALIGNED MEDICAL SOLUTIONS medical convenience kits labeled as: 1) Nerve Block Tray - RX, Part Number AMS13975A; 2) Universal Block Tray- RX, Part Number AMS2009; 3) Nerve Block Tray - RX, Part Number AMS3224.
AMS ALIGNED MEDICAL SOLUTIONS medical convenience kits labeled as: 1) Nerve Block Tray - RX, Part Number AMS13975A; 2) Universal Block Tray- RX, Part Number AMS2009; 3) Nerve Block Tray - RX, Part Number AMS3224.
Windstone Medical Packaging issued a recall for specific item(s) and lot(s) of Aligned Medical Solutions (AMS) convenience kits containing Elevaris Lidocaine HCl injection USP. Elevaris Medical Devices Inc. recalled the Lidocaine HCl injection USP due to supplier quality issues.
Power Over Fiber Base Module
Power Over Fiber Base Module
Device not certified - no laser product report was filed with CDRH prior to distribution. Product label incorrectly states device is "Class IV", although Class 1 is appropriate for device. Improperly labeled - omitted labels required under 21 CFR 1040.10 / IEC 60825-1 via LN#56. Missing certification and proper manufacturer's ID label. Was not accompanied by compliant User Information. Formalized quality control procedures and record keeping of QC testing was not performed to IEC 60825-1 nor 21 CFR 1040.10 standards. Sales information did not convey required class designation and warning statement
EOPA 3D Arterial Cannula DIL TIP 22FR, intended for use with cardiopulmonary bypass as an arterial return cannula, Model Number 78222
EOPA 3D Arterial Cannula DIL TIP 22FR, intended for use with cardiopulmonary bypass as an arterial return cannula, Model Number 78222
Pinhole leaks may occur in the wire-wound body during cardiopulmonary bypass. Potential risks associated with this condition may include hypovolemia, vessel laceration or perforation, hypotension, ischemia, and organ dysfunction.
Brand Name: GEM Premier 5000 Product Name: GEM Premier 5000 Model/Catalog Number: 00024019255 portable blood analyzer system
Brand Name: GEM Premier 5000 Product Name: GEM Premier 5000 Model/Catalog Number: 00024019255 portable blood analyzer system
Potential for Bar Code Reader (BCR) wands, used with the GEM Premier 5000 and GEM Premier 7000 systems, to assign patient results to an incorrect patient ID.
AMS ALIGNED MEDICAL SOLUTIONS medical convenience kits labeled as: SPINAL KIT, Part Number AMS13683A
AMS ALIGNED MEDICAL SOLUTIONS medical convenience kits labeled as: SPINAL KIT, Part Number AMS13683A
Windstone Medical Packaging issued a recall for specific item(s) and lot(s) of Aligned Medical Solutions (AMS) convenience kits containing Elevaris Lidocaine HCl injection USP. Elevaris Medical Devices Inc. recalled the Lidocaine HCl injection USP due to supplier quality issues.
Stryker Hoffmann II Connecting Rod Micro 3 x 120mm. Catalog Number: 50796120.
Stryker Hoffmann II Connecting Rod Micro 3 x 120mm. Catalog Number: 50796120.
Potential cracking of the Hoffmann II Carbon Connecting Rods following cleaning and sterilization.
Ingenuity CT CT5000 Ingenuity Plus CT5000 Ingenuity Pro CT5000 Ingenuity Premium Ingenuity CT Upgrades Ingenuity CT China Ingenuity Core 128 Elite Brazil
Ingenuity CT CT5000 Ingenuity Plus CT5000 Ingenuity Pro CT5000 Ingenuity Premium Ingenuity CT Upgrades Ingenuity CT China Ingenuity Core 128 Elite Brazil
The clinical CT scan may not automatically trigger after the Bolus Tracking scan and may need to be triggered manually. Additional Bolus Tracking shots may occur. This may result in the clinical acquisition being inadequate for diagnosis, causing a potential for patient rescan and receiving additional radiation.
EOPA Elongated One-Piece Arterial Cannula DIL TIP 22FR, intended for use with cardiopulmonary bypass as an arterial return cannula, Model Number 77622
EOPA Elongated One-Piece Arterial Cannula DIL TIP 22FR, intended for use with cardiopulmonary bypass as an arterial return cannula, Model Number 77622
Pinhole leaks may occur in the wire-wound body during cardiopulmonary bypass. Potential risks associated with this condition may include hypovolemia, vessel laceration or perforation, hypotension, ischemia, and organ dysfunction.
EOPA Elongated One-Piece Arterial Cannula DIL TIP 22FR, intended for use with cardiopulmonary bypass as an arterial return cannula, Model Number 77722
EOPA Elongated One-Piece Arterial Cannula DIL TIP 22FR, intended for use with cardiopulmonary bypass as an arterial return cannula, Model Number 77722
Pinhole leaks may occur in the wire-wound body during cardiopulmonary bypass. Potential risks associated with this condition may include hypovolemia, vessel laceration or perforation, hypotension, ischemia, and organ dysfunction.
Permobil M3 Corpus Power Wheelchair with Heavy Duty Shock REF:120031, Model version 3
Permobil M3 Corpus Power Wheelchair with Heavy Duty Shock REF:120031, Model version 3
This recall has been reported retroactively. The power wheelchair firmware lacks a speed restriction to maintain stability when the seat lift exceeds 50 mm, which may cause the user to fall from the wheelchair or the wheelchair to tip over,
Brand Name: GEM Premier 5000 Product Name: GEM Premier 5000 Model/Catalog Number: 00024019255 Portable blood analyzer system
Brand Name: GEM Premier 5000 Product Name: GEM Premier 5000 Model/Catalog Number: 00024019255 Portable blood analyzer system
Potential for Bar Code Reader (BCR) wands, used with the GEM Premier 5000 and GEM Premier 7000 systems, to assign patient results to an incorrect patient ID.
Stryker Hoffmann II Connecting Rod Micro 3 x 50mm. Catalog Number: 50796050.
Stryker Hoffmann II Connecting Rod Micro 3 x 50mm. Catalog Number: 50796050.
Potential cracking of the Hoffmann II Carbon Connecting Rods following cleaning and sterilization.
Stryker Hoffmann II Connecting Rod Micro 3 x 150mm. Catalog Number: 50796150.
Stryker Hoffmann II Connecting Rod Micro 3 x 150mm. Catalog Number: 50796150.
Potential cracking of the Hoffmann II Carbon Connecting Rods following cleaning and sterilization.
Brand Name: GEM Premier 5000 Product Name: GEM Premier 5000 Model/Catalog Number: 00024019255 Portable blood analyzer system
Brand Name: GEM Premier 5000 Product Name: GEM Premier 5000 Model/Catalog Number: 00024019255 Portable blood analyzer system
Potential for Bar Code Reader (BCR) wands, used with the GEM Premier 5000 and GEM Premier 7000 systems, to assign patient results to an incorrect patient ID.
AMS ALIGNED MEDICAL SOLUTIONS medical convenience kits labeled as: 1) Laminectomy Pack, Pack Number AMS13574A; 2) ACDF/Fusion Pack, Pack Number AMS14710B; 3) Spine Pack, Pack Number AMS14991A; 4) Spine Pack, Pack Number AMS14991B; 5) Spinal Pack, Pack Number AMS16278; 6) Spine Pack, Pack Number AMS16499; 7) Spine Pack, Pack Number AMS16709; 8) Lumbar Spine Pack, Pack Number AMS17336; 9) Laminectomy Pack, Pack Number AMS17945; 10) Anterior Cervical Pack, Pack Number AMS17946; 11) Spine Pack, Pack Number AMS3150F; 12) Spine Pack, Pack Number AMS3150G; 13) Spine Pack, Pack Number AMS5451D; 14) ENT Pack, Pack Number AMS9771.
AMS ALIGNED MEDICAL SOLUTIONS medical convenience kits labeled as: 1) Laminectomy Pack, Pack Number AMS13574A; 2) ACDF/Fusion Pack, Pack Number AMS14710B; 3) Spine Pack, Pack Number AMS14991A; 4) Spine Pack, Pack Number AMS14991B; 5) Spinal Pack, Pack Number AMS16278; 6) Spine Pack, Pack Number AMS16499; 7) Spine Pack, Pack Number AMS16709; 8) Lumbar Spine Pack, Pack Number AMS17336; 9) Laminectomy Pack, Pack Number AMS17945; 10) Anterior Cervical Pack, Pack Number AMS17946; 11) Spine Pack, Pack Number AMS3150F; 12) Spine Pack, Pack Number AMS3150G; 13) Spine Pack, Pack Number AMS5451D; 14) ENT Pack, Pack Number AMS9771.
The recall notice was initiated due to a Medicom Urgent Medical Device Recall. Medicom is recalling specific lots of Ritmed¿ Neurological Sponges Non-Sterile Models 55992C to 55998C due to potential for unexpected variability of endotoxin levels on the products.