VANTAGE GALAN 3T Model MRT-3020/MEXL-3020
VANTAGE GALAN 3T Model MRT-3020/MEXL-3020
There is a potential for formation of ice occurring in the venting system of the superconducting magnet of the MRI systems. if a quench occurs in this condition, helium gas may not be able to escape via the designed vent paths, and the pressure in the helium vessel may rise. This pressure build-up could eventually rupture the helium vessel, causing helium gas to be released into the MR scanning room.
FreeStyle Libre 3 Plus Sensor REF 78769-01 UDI-DI code: 00357599843014 The FreeStyle Libre 3 Plus sensor is a component of the FreeStyle Libre 3 Continuous Glucose Monitoring System.
FreeStyle Libre 3 Plus Sensor REF 78769-01 UDI-DI code: 00357599843014 The FreeStyle Libre 3 Plus sensor is a component of the FreeStyle Libre 3 Continuous Glucose Monitoring System.
Due to a manufacturing process issue that may cause carbon build up in the sensor that may result in incorrect low glucose results
Medline medical procedure convenience kits labeled as: KIT ROBOTICS UROLOGY PROSTATE, REF DYKMBNDL116G
Medline medical procedure convenience kits labeled as: KIT ROBOTICS UROLOGY PROSTATE, REF DYKMBNDL116G
Medline kits containing Stryker's Strykeflow 2 Suction Irrigators due to a change in design in 2024, irrigation solution is able to travel to the handpiece and battery pack during use of the Strykeflow 2 Suction Irrigator. This design change has caused some devices to leak and/or emit vaporized saline (which can resemble smoke) during use.
Medicrea, IB3D PL Instruments Set, Rx Only REF: SPS03174
Medicrea, IB3D PL Instruments Set, Rx Only REF: SPS03174
Due to complaints, orthopedic rotation tool handle may untread from the shaft resulting in the inability to rotate implant.
Medline Kits containing B. Braun IV Administration Sets and Pump Administration Sets, labeled as: 1) DRAWER 2 IV SUPPLIES, Medline kit SKU ACC010271B; 2) DRAWER 2 IV FLUIDS & TUBING, Medline kit SKU ACC010416B; 3) OXYGENATION & TUBING TRAY, Medline kit SKU ACC010525C; 4) TOP DRAWER #6, Medline kit SKU ACC010688; 5) RRMC CODE CART DRAWER 3, Medline kit SKU ACC010770; 6) SURGERY BAG, Medline kit SKU DYKM1279C; 7) ADMISSION KIT, Medline kit SKU DYKS1179; 8) PRE OP KIT, Medline kit SKU DYKS1192C; 9) MEDLINE PEDIATRIC PATIENT PACK, Medline kit SKU DYKS1199B; 10) MEDLINE ADULT PATIENT PACKAGE, Medline kit SKU DYKS1200B; 11) GERMANTOWN PRE OP KIT, Medline kit SKU DYKS1248; 12) GERMANTOWN PRE OP BLOCK KIT, Medline kit SKU DYKS1249; 13) PRE OP KIT, Medline kit SKU DYKS1274A; 14) CATH LAB PRE OP START KIT, Medline kit SKU DYKS1324; 15) PRE OP KIT, Medline kit SKU DYKS1376; 16) PTC KIT, Medline kit SKU DYNDH1161A; 17) DR BROWN BODY, Medline kit SKU DYNJ910487.
Medline Kits containing B. Braun IV Administration Sets and Pump Administration Sets, labeled as: 1) DRAWER 2 IV SUPPLIES, Medline kit SKU ACC010271B; 2) DRAWER 2 IV FLUIDS & TUBING, Medline kit SKU ACC010416B; 3) OXYGENATION & TUBING TRAY, Medline kit SKU ACC010525C; 4) TOP DRAWER #6, Medline kit SKU ACC010688; 5) RRMC CODE CART DRAWER 3, Medline kit SKU ACC010770; 6) SURGERY BAG, Medline kit SKU DYKM1279C; 7) ADMISSION KIT, Medline kit SKU DYKS1179; 8) PRE OP KIT, Medline kit SKU DYKS1192C; 9) MEDLINE PEDIATRIC PATIENT PACK, Medline kit SKU DYKS1199B; 10) MEDLINE ADULT PATIENT PACKAGE, Medline kit SKU DYKS1200B; 11) GERMANTOWN PRE OP KIT, Medline kit SKU DYKS1248; 12) GERMANTOWN PRE OP BLOCK KIT, Medline kit SKU DYKS1249; 13) PRE OP KIT, Medline kit SKU DYKS1274A; 14) CATH LAB PRE OP START KIT, Medline kit SKU DYKS1324; 15) PRE OP KIT, Medline kit SKU DYKS1376; 16) PTC KIT, Medline kit SKU DYNDH1161A; 17) DR BROWN BODY, Medline kit SKU DYNJ910487.
Medline kits contain B. Braun IV Administration Sets and Pump Administration Sets which were recalled due to customer complaints identifying that the check valve components may become stuck in the open or closed positions.
BD Ready-to-Use Hydrophilic Catheter 14 Fr (4.7 mm) Straight Tip, Coated, Female REF: RTU14F
BD Ready-to-Use Hydrophilic Catheter 14 Fr (4.7 mm) Straight Tip, Coated, Female REF: RTU14F
Labeling error, Incorrect expiration date
Medline Kits containing B. Braun IV Administration Sets and Pump Administration Sets, labeled as: NEURO ANGIO PACK, Medline kit SKU DYNJ38935
Medline Kits containing B. Braun IV Administration Sets and Pump Administration Sets, labeled as: NEURO ANGIO PACK, Medline kit SKU DYNJ38935
Medline kits contain B. Braun IV Administration Sets and Pump Administration Sets which were recalled due to customer complaints identifying that the check valve components may become stuck in the open or closed positions.
Allura Xper FD10/10; Model Number: 722027;
Allura Xper FD10/10; Model Number: 722027;
Philips has identified that in a limited number of impacted systems the drip tray beneath the cooling unit was not installed under previous field corrections, or evidence of the implementation was not adequately documented. If it is not installed, there is a potential for coolant liquid to contact electrical components. This could lead to electrical short-circuits, which may trigger system fuses and result in system shutdown.
SMV DSX New Line, System, Tomography, Computed, Emission
SMV DSX New Line, System, Tomography, Computed, Emission
GE HealthCare has become aware that certain Nuclear Medicine systems that are past the End of Guaranteed Service (herein referred to as Impacted Systems and listed in the Affected Product Details section of this letter) could have been transported or relocated without adequate detector support. This could result in excessive stress being applied to the detector mounting mechanisms, compromising their integrity. If this occurs, it can potentially result in a detector fall and lead to life-threatening bodily injury. There have been no reports of detector falls or injuries as a result of this potential issue. The Impacted Systems affected by this notice are those that have not been manufactured for several years. GE HealthCare has previously communicated End of Guaranteed Service for these Impacted Systems.
Portex Spinal Tray, Item No. A3729-24 A3595
Portex Spinal Tray, Item No. A3729-24 A3595
Affected lots of syringes may have a crack on the syringe collar, which may lead to delayed or repeated blood draw/fluid delivery. This issue may also lead to blood leakage during sampling of arterial blood or leakage during fluid delivery.
Product Name: Allura Xper FD10C; Model number: 722001;
Product Name: Allura Xper FD10C; Model number: 722001;
Philips has identified that in a limited number of impacted systems the drip tray beneath the cooling unit was not installed under previous field corrections, or evidence of the implementation was not adequately documented. If it is not installed, there is a potential for coolant liquid to contact electrical components. This could lead to electrical short-circuits, which may trigger system fuses and result in system shutdown.
SMV BodyTrack, System, Tomography, Computed, Emission
SMV BodyTrack, System, Tomography, Computed, Emission
GE HealthCare has become aware that certain Nuclear Medicine systems that are past the End of Guaranteed Service (herein referred to as Impacted Systems and listed in the Affected Product Details section of this letter) could have been transported or relocated without adequate detector support. This could result in excessive stress being applied to the detector mounting mechanisms, compromising their integrity. If this occurs, it can potentially result in a detector fall and lead to life-threatening bodily injury. There have been no reports of detector falls or injuries as a result of this potential issue. The Impacted Systems affected by this notice are those that have not been manufactured for several years. GE HealthCare has previously communicated End of Guaranteed Service for these Impacted Systems.
Allura Xper FD20 Biplane; Model Number: 722013;
Allura Xper FD20 Biplane; Model Number: 722013;
Philips has identified that in a limited number of impacted systems the drip tray beneath the cooling unit was not installed under previous field corrections, or evidence of the implementation was not adequately documented. If it is not installed, there is a potential for coolant liquid to contact electrical components. This could lead to electrical short-circuits, which may trigger system fuses and result in system shutdown.
Allura Xper FD20/20; Model Number: 722038;
Allura Xper FD20/20; Model Number: 722038;
Philips has identified that in a limited number of impacted systems the drip tray beneath the cooling unit was not installed under previous field corrections, or evidence of the implementation was not adequately documented. If it is not installed, there is a potential for coolant liquid to contact electrical components. This could lead to electrical short-circuits, which may trigger system fuses and result in system shutdown.
Allura Xper FD20; Model Number: 722006;
Allura Xper FD20; Model Number: 722006;
Philips has identified that in a limited number of impacted systems the drip tray beneath the cooling unit was not installed under previous field corrections, or evidence of the implementation was not adequately documented. If it is not installed, there is a potential for coolant liquid to contact electrical components. This could lead to electrical short-circuits, which may trigger system fuses and result in system shutdown.
Allura Xper FD10; Model Number: 722026;
Allura Xper FD10; Model Number: 722026;
Philips has identified that in a limited number of impacted systems the drip tray beneath the cooling unit was not installed under previous field corrections, or evidence of the implementation was not adequately documented. If it is not installed, there is a potential for coolant liquid to contact electrical components. This could lead to electrical short-circuits, which may trigger system fuses and result in system shutdown.
FreeStyle Libre 3 Plus Sensor REF 78768-01 UDI-DI code: 00357599844011 The FreeStyle Libre 3 Plus sensor is a component of the FreeStyle Libre 3 Continuous Glucose Monitoring System.
FreeStyle Libre 3 Plus Sensor REF 78768-01 UDI-DI code: 00357599844011 The FreeStyle Libre 3 Plus sensor is a component of the FreeStyle Libre 3 Continuous Glucose Monitoring System.
Due to a manufacturing process issue that may cause carbon build up in the sensor that may result in incorrect low glucose results
Abre Venous Self-Expanding Stent System, Model numbers AB9G14120090 AB9G12100090 AB9G14080090 AB9G12080090 AB9U12060090 AB9U14100090 AB9U14080090 AB9U12080090 AB9U14060090 AB9G14100090 AB9G12060090
Abre Venous Self-Expanding Stent System, Model numbers AB9G14120090 AB9G12100090 AB9G14080090 AB9G12080090 AB9U12060090 AB9U14100090 AB9U14080090 AB9U12080090 AB9U14060090 AB9G14100090 AB9G12060090
Stents may be impacted by a Nitinol anomaly which causes a reduced stent diameter when deployed and corresponding reduced radial force. Issue may result in stent migration.
FreeStyle Libre 3 Sensor REF 72081-01 UDI-DI code: 00357599818005 The FreeStyle Libre 3 sensor is a component of the FreeStyle Libre 3 Continuous Glucose Monitoring System.
FreeStyle Libre 3 Sensor REF 72081-01 UDI-DI code: 00357599818005 The FreeStyle Libre 3 sensor is a component of the FreeStyle Libre 3 Continuous Glucose Monitoring System.
Due to a manufacturing process issue that may cause carbon build up in the sensor that may result in incorrect low glucose results
A71200 Vanta" Clinician Programmer Application (CP App) version 2.0.2465 and 2.0.2683, Product number A71200. Software is deployed and operated on Samsung tablets (CFN CT900).
A71200 Vanta" Clinician Programmer Application (CP App) version 2.0.2465 and 2.0.2683, Product number A71200. Software is deployed and operated on Samsung tablets (CFN CT900).
Complaints received that Vanta A71200 CP App does not function as intended during use. There is a potential for prolonged or postponed surgical procedure.
Detachable 10in Pendant Upgrade component for the AIRO Computed Tomography (CT) X-ray System.
Detachable 10in Pendant Upgrade component for the AIRO Computed Tomography (CT) X-ray System.
AIRO pendant replacement kits and upgrade do not possess the "Safe Hand Position Warning" label.
da Vinci SP, SP Access Port Kit, Large Incision Reference Numbers:430073 (2.7-4cm,SP1098, Box) & 430075 (2.7-7cm,SP1098,Box)
da Vinci SP, SP Access Port Kit, Large Incision Reference Numbers:430073 (2.7-4cm,SP1098, Box) & 430075 (2.7-7cm,SP1098,Box)
Access Port System tray may develop cracks potentially resulting in a sterility breach.
Philips Azurion Systems with software versions R2.1.10 and R2.2.10. Includes the following label descriptions and corresponding models: 1. Azurion 3 M12. Model Numbers: 722063, 722221. 2. Azurion 3 M15. Model Numbers: 722064, 722222, 722280. 3. Azurion 5 M12. Model Number: 722227. 4. Azurion 5 M20. Model Numbers: 722228, 722281. 5. Azurion 7 B12. Model Numbers: 722067, 722225. 6. Azurion 7 B20. Model Numbers: 722068, 722226. 7. Azurion 7 M12. Model Numbers: 722078, 722223. 8. Azurion 7 M20. Model Numbers: 722079, 722224, 722282.
Philips Azurion Systems with software versions R2.1.10 and R2.2.10. Includes the following label descriptions and corresponding models: 1. Azurion 3 M12. Model Numbers: 722063, 722221. 2. Azurion 3 M15. Model Numbers: 722064, 722222, 722280. 3. Azurion 5 M12. Model Number: 722227. 4. Azurion 5 M20. Model Numbers: 722228, 722281. 5. Azurion 7 B12. Model Numbers: 722067, 722225. 6. Azurion 7 B20. Model Numbers: 722068, 722226. 7. Azurion 7 M12. Model Numbers: 722078, 722223. 8. Azurion 7 M20. Model Numbers: 722079, 722224, 722282.
Six (6) identified software issues which may result in the following: system keeps restarting, AMC triple drive, C-Partition of Suite PC running out of free space, system remains in continuous restart mode after the start-up, misalignment of Market Tool Overlay, and longitudinal positional error.
Allura Xper FD10; Model Number: 722010;
Allura Xper FD10; Model Number: 722010;
Philips has identified that in a limited number of impacted systems the drip tray beneath the cooling unit was not installed under previous field corrections, or evidence of the implementation was not adequately documented. If it is not installed, there is a potential for coolant liquid to contact electrical components. This could lead to electrical short-circuits, which may trigger system fuses and result in system shutdown.